High-Accuracy Volumetric Measurements of Soft Tissues Using Robotic 3D Scanner
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F15%3APU114791" target="_blank" >RIV/00216305:26220/15:PU114791 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ifacol.2015.07.054" target="_blank" >http://dx.doi.org/10.1016/j.ifacol.2015.07.054</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ifacol.2015.07.054" target="_blank" >10.1016/j.ifacol.2015.07.054</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Accuracy Volumetric Measurements of Soft Tissues Using Robotic 3D Scanner
Popis výsledku v původním jazyce
This paper introduces novel high-accuracy method for volumetric measurements of soft tissues, which is more accurate compared to present commonly used standard methods in medical domain. First part deals with summary of today's standard methods with focus on its accuracy, then principles of the new method are discussed and its accuracy is presented. Finally, the novel method is compared with standard ones. Accuracy dening equations are experimentally veried in the last section of this paper. The method is based on capturing 3D model of patients body using Robotic 3D Scanner followed by computing of volume or surface area. Besides the high-accuracy of measurement, such 3D model is usable for many other purposes, like monitoring of recovery process, ergonomic splint manufacturing or inammation detection.
Název v anglickém jazyce
High-Accuracy Volumetric Measurements of Soft Tissues Using Robotic 3D Scanner
Popis výsledku anglicky
This paper introduces novel high-accuracy method for volumetric measurements of soft tissues, which is more accurate compared to present commonly used standard methods in medical domain. First part deals with summary of today's standard methods with focus on its accuracy, then principles of the new method are discussed and its accuracy is presented. Finally, the novel method is compared with standard ones. Accuracy dening equations are experimentally veried in the last section of this paper. The method is based on capturing 3D model of patients body using Robotic 3D Scanner followed by computing of volume or surface area. Besides the high-accuracy of measurement, such 3D model is usable for many other purposes, like monitoring of recovery process, ergonomic splint manufacturing or inammation detection.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20204 - Robotics and automatic control
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
13th IFAC Conference on Programmable Devices and Embedded Systems - PDeS 2015
ISBN
—
ISSN
1474-6670
e-ISSN
—
Počet stran výsledku
504
Strana od-do
318-323
Název nakladatele
Elsevier
Místo vydání
Krakow, Polsko
Místo konání akce
Krakow
Datum konání akce
13. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000375804500055