Real-time measurement of cardiomyocyte contraction and calcium transients using fast image processing algorithms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F15%3APU116337" target="_blank" >RIV/00216305:26220/15:PU116337 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-19387-8_62" target="_blank" >http://dx.doi.org/10.1007/978-3-319-19387-8_62</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-19387-8_62" target="_blank" >10.1007/978-3-319-19387-8_62</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-time measurement of cardiomyocyte contraction and calcium transients using fast image processing algorithms
Popis výsledku v původním jazyce
An improved technique for recording of contrac-tion of heart cells simultaneously with recording of calcium transients by fluorescence method is introduced. The tech-nique aims to quantify contractions under conditions including low image quality caused by reduced transmitted light. The proposed methods allow more accurate detection, lower error rate using the up-to-date image processing, and automation of the process comparing to recent approaches. The technique is compared with direct optical measurement method using processing of two-dimensional digital images of the cardiac cell. The technique is improved to be fast enough to be includ-ed in the system for real-time measurements.
Název v anglickém jazyce
Real-time measurement of cardiomyocyte contraction and calcium transients using fast image processing algorithms
Popis výsledku anglicky
An improved technique for recording of contrac-tion of heart cells simultaneously with recording of calcium transients by fluorescence method is introduced. The tech-nique aims to quantify contractions under conditions including low image quality caused by reduced transmitted light. The proposed methods allow more accurate detection, lower error rate using the up-to-date image processing, and automation of the process comparing to recent approaches. The technique is compared with direct optical measurement method using processing of two-dimensional digital images of the cardiac cell. The technique is improved to be fast enough to be includ-ed in the system for real-time measurements.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10610 - Biophysics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Congress on Medical Physics and Biomedical Engineering
ISBN
978-3-319-19386-1
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
256-259
Název nakladatele
Springer International Publishing
Místo vydání
Neuveden
Místo konání akce
Toronto
Datum konání akce
7. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000381813000062