Automatic detection of P wave during the second-degree AV block is the main condition for automatic detection of this pathology. This work deals with developing of the algorithm for P wave detection. The algorithm is appropriate for ECG signals with AV block as well as signals with other rhythm types (it does not produce false positive P wave detections). For P wave detection, the phasor transform is applied and several innovative rules are created. These rules are based on knowledge of heart manifestation during both physiological and pathological heart function. The proposed algorithm consists of four parts – filtration, QRS complex detection, application of rules, and P wave detection. The accuracy of the P wave detection algorithm is 99.84 % for signals with AV block, and 99.85 % for signals without any pathologies.
Název v anglickém jazyce
Detection of P Wave During Second-Degree Atrioventricular Block in Ecg Signals
Popis výsledku anglicky
Automatic detection of P wave during the second-degree AV block is the main condition for automatic detection of this pathology. This work deals with developing of the algorithm for P wave detection. The algorithm is appropriate for ECG signals with AV block as well as signals with other rhythm types (it does not produce false positive P wave detections). For P wave detection, the phasor transform is applied and several innovative rules are created. These rules are based on knowledge of heart manifestation during both physiological and pathological heart function. The proposed algorithm consists of four parts – filtration, QRS complex detection, application of rules, and P wave detection. The accuracy of the P wave detection algorithm is 99.84 % for signals with AV block, and 99.85 % for signals without any pathologies.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20204 - Robotics and automatic control
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 23st Conference STUDENT EEICT 2017
ISBN
978-80-214-5496-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
655-659
Název nakladatele
Vysoké učení technické, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
27. 4. 2017
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—