Lead-Acid Battery Evaluation Based on Open Circuit Voltage Fluctuation Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F17%3APU123521" target="_blank" >RIV/00216305:26220/17:PU123521 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.utee.feec.vutbr.cz/eeict/2017/EEICT%202017-sborn%C3%ADk-komplet.pdf" target="_blank" >http://www.utee.feec.vutbr.cz/eeict/2017/EEICT%202017-sborn%C3%ADk-komplet.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lead-Acid Battery Evaluation Based on Open Circuit Voltage Fluctuation Measurement
Popis výsledku v původním jazyce
The state of charge and the state of health are two crucial parameters of batteries. Current state of the art methods of their estimation include some as simple as measuring open circuit voltage, all the way to fuzzy logic estimation and constant online battery overview. Some main problems of such methods are either the length of single parameter evaluation cycle, or their inherent inaccuracy due to limitations in battery manufacture precision. This article proposes novel method of the lead-acid battery state of the health estimation, based on open circuit noise measurement. It reports the nature of changes in low frequency noise spectral density, that occur after catastrophic self-discharge failure or avalanche voltage drop in lead-acid batteries.
Název v anglickém jazyce
Lead-Acid Battery Evaluation Based on Open Circuit Voltage Fluctuation Measurement
Popis výsledku anglicky
The state of charge and the state of health are two crucial parameters of batteries. Current state of the art methods of their estimation include some as simple as measuring open circuit voltage, all the way to fuzzy logic estimation and constant online battery overview. Some main problems of such methods are either the length of single parameter evaluation cycle, or their inherent inaccuracy due to limitations in battery manufacture precision. This article proposes novel method of the lead-acid battery state of the health estimation, based on open circuit noise measurement. It reports the nature of changes in low frequency noise spectral density, that occur after catastrophic self-discharge failure or avalanche voltage drop in lead-acid batteries.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EEICT proceedings of the 23rd conference
ISBN
9788021454965
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
685-689
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
27. 4. 2017
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—