Popis výsledku v původním jazyce
The paper deals with the power loss distribution along the arc heater with intensively blasted electric arc and compares the measured power loss of individual parts of the arc heater and power loss computed using a simple model of the electric arc. In previous works, the authors have presented the simple model of electric arc burning in the arc heater channel. Measured integral quantities obtained during numerous experiments served as input data of the model and attention has been focused at finding the development of the arc radius and temperature along the arc heater’s channel that meets the experimentally obtained integral values as a whole. In this contribution, the arc heater is divided into several parts whose power loss is measured and computed separately. For this purpose, the arc model has been adopted to make it possible. The aim is to obtain more detailed information on processes taking place in individual parts of the arc heater. The results reveal that for the input and main part of the arc heater’s anode channel the computed and measured power loss differ mutually in opposite sense. This observation raises new questions concerning the suit-ability of presumptions, approximations and/or simplifications used in the modelling. Further experiments and computations are needed. The conclusions can be useful for the design of similar devices, and for more precise modelling of the behavior of electric arc inside the arc heater channel.
Název v anglickém jazyce
Power Loss Distribution along the Arc Heater with Intensively Blasted Electric Arc
Popis výsledku anglicky
The paper deals with the power loss distribution along the arc heater with intensively blasted electric arc and compares the measured power loss of individual parts of the arc heater and power loss computed using a simple model of the electric arc. In previous works, the authors have presented the simple model of electric arc burning in the arc heater channel. Measured integral quantities obtained during numerous experiments served as input data of the model and attention has been focused at finding the development of the arc radius and temperature along the arc heater’s channel that meets the experimentally obtained integral values as a whole. In this contribution, the arc heater is divided into several parts whose power loss is measured and computed separately. For this purpose, the arc model has been adopted to make it possible. The aim is to obtain more detailed information on processes taking place in individual parts of the arc heater. The results reveal that for the input and main part of the arc heater’s anode channel the computed and measured power loss differ mutually in opposite sense. This observation raises new questions concerning the suit-ability of presumptions, approximations and/or simplifications used in the modelling. Further experiments and computations are needed. The conclusions can be useful for the design of similar devices, and for more precise modelling of the behavior of electric arc inside the arc heater channel.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
18th International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-5090-6405-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
682-687
Název nakladatele
VŠB-Technical University of Ostrava
Místo vydání
Ostrava, CR
Místo konání akce
Kouty nad Desnou
Datum konání akce
17. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000422921000126