Application of SWT for Heart Rate Monitoring Using Smartphone Camera
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F17%3APU124439" target="_blank" >RIV/00216305:26220/17:PU124439 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.radio.feec.vutbr.cz/ieee/userfiles/downloads/archive/2017-Mikulov/Proceedings_Mikulov_2017.pdf" target="_blank" >http://www.radio.feec.vutbr.cz/ieee/userfiles/downloads/archive/2017-Mikulov/Proceedings_Mikulov_2017.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of SWT for Heart Rate Monitoring Using Smartphone Camera
Popis výsledku v původním jazyce
Monitoring of heart rate using smartphone is very popular nowadays. There exist some applications for smartphone with usually unknown accuracy. But there is no certified application for this purpose. The article introduces new method for heart rate monitoring which uses smartphone´s built-in camera and LED light. The algorithm is based on extraction of photoplethysmogram and use of stationary wavelet transform. 52 various wavelets were tested in terms of their suitability for heart rate monitoring. The accuracy is compared with heart rate estimated from electrocardiogram. In the range of 55-111 bpm, the heart rate can be estimated with mean error of 0.4093 bpm and maximum error of 0.8458 bpm. The recommended settings of the algorithm is to use green photoplethysmogram (green color channel of the video), provide stationary wavelet transform with 6-level decomposition, rbio2.4 wavelet, and calculate heart rate using PPG peaks’ distance. Data of lower and higher heart rate were tested as well.
Název v anglickém jazyce
Application of SWT for Heart Rate Monitoring Using Smartphone Camera
Popis výsledku anglicky
Monitoring of heart rate using smartphone is very popular nowadays. There exist some applications for smartphone with usually unknown accuracy. But there is no certified application for this purpose. The article introduces new method for heart rate monitoring which uses smartphone´s built-in camera and LED light. The algorithm is based on extraction of photoplethysmogram and use of stationary wavelet transform. 52 various wavelets were tested in terms of their suitability for heart rate monitoring. The accuracy is compared with heart rate estimated from electrocardiogram. In the range of 55-111 bpm, the heart rate can be estimated with mean error of 0.4093 bpm and maximum error of 0.8458 bpm. The recommended settings of the algorithm is to use green photoplethysmogram (green color channel of the video), provide stationary wavelet transform with 6-level decomposition, rbio2.4 wavelet, and calculate heart rate using PPG peaks’ distance. Data of lower and higher heart rate were tested as well.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20204 - Robotics and automatic control
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of IEEE Student Branch Conference Mikulov 2017
ISBN
978-80-214-5526-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
49-52
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Mikulov, Czech republic
Datum konání akce
28. 8. 2017
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—