Increasing the Efficiency of Induction Generator in Small Hydro Power Plant for Varying River Flow Rate
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F17%3APU124450" target="_blank" >RIV/00216305:26220/17:PU124450 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/chapter/10.1007/978-3-319-65960-2_22" target="_blank" >https://link.springer.com/chapter/10.1007/978-3-319-65960-2_22</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-65960-2_22" target="_blank" >10.1007/978-3-319-65960-2_22</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Increasing the Efficiency of Induction Generator in Small Hydro Power Plant for Varying River Flow Rate
Popis výsledku v původním jazyce
This paper deals with improving efficiency of a small hydro power plant that not operates in nominal power, but in lower power. Efficiency is lower in this low power operation than in nominal power operation since constant no-load losses. These no-load losses can be varied by changing stator voltage and it may produce higher efficiency. Relation between efficiency, power operation and stator voltage are presented and the highest possible efficiency is highlighted. This process is made for typical 15 kW small hydro power plant with horizontal Francis turbine. Finally, there is comparison between original efficiency of generator and improved efficiency with corresponding stator voltage and one year power savings.
Název v anglickém jazyce
Increasing the Efficiency of Induction Generator in Small Hydro Power Plant for Varying River Flow Rate
Popis výsledku anglicky
This paper deals with improving efficiency of a small hydro power plant that not operates in nominal power, but in lower power. Efficiency is lower in this low power operation than in nominal power operation since constant no-load losses. These no-load losses can be varied by changing stator voltage and it may produce higher efficiency. Relation between efficiency, power operation and stator voltage are presented and the highest possible efficiency is highlighted. This process is made for typical 15 kW small hydro power plant with horizontal Francis turbine. Finally, there is comparison between original efficiency of generator and improved efficiency with corresponding stator voltage and one year power savings.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1210" target="_blank" >LO1210: Energie v podmínkách udržitelného rozvoje (EN-PUR)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Mechatronics 2017
ISBN
978-3-319-65959-6
ISSN
2194-5357
e-ISSN
—
Počet stran výsledku
8
Strana od-do
169-176
Název nakladatele
Springer International Publishing
Místo vydání
Cham
Místo konání akce
Brno
Datum konání akce
6. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000554435500022