Automatic System for Diseased Artery Transverse Section Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F18%3APU127221" target="_blank" >RIV/00216305:26220/18:PU127221 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/SPIN.2018.8474262" target="_blank" >http://dx.doi.org/10.1109/SPIN.2018.8474262</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SPIN.2018.8474262" target="_blank" >10.1109/SPIN.2018.8474262</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automatic System for Diseased Artery Transverse Section Detection
Popis výsledku v původním jazyce
This article deals with an artery transversal section detection from ultrasound medical images. Exact localization of artery is needed for measuring artery properties, which can be used for diagnosing vascular diseases such as atherosclerosis, hypoplasia. Image processing methods are non-invasive, fast and cheap. In this work, the Viola-Jones object detector was used and further adopted for artery detection problem. In comparison with the other approaches created method improves speed and accuracy of detection mainly for unhealthy arteries. Created methods achieves 96% accuracy for healthy arteries and 95% accuracy of detection for unhealthy arteries. Average detection time per image was 2.5 milliseconds.
Název v anglickém jazyce
Automatic System for Diseased Artery Transverse Section Detection
Popis výsledku anglicky
This article deals with an artery transversal section detection from ultrasound medical images. Exact localization of artery is needed for measuring artery properties, which can be used for diagnosing vascular diseases such as atherosclerosis, hypoplasia. Image processing methods are non-invasive, fast and cheap. In this work, the Viola-Jones object detector was used and further adopted for artery detection problem. In comparison with the other approaches created method improves speed and accuracy of detection mainly for unhealthy arteries. Created methods achieves 96% accuracy for healthy arteries and 95% accuracy of detection for unhealthy arteries. Average detection time per image was 2.5 milliseconds.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 5th International Conference on Signal Processing and Integrated Networks (SPIN)
ISBN
978-1-5386-3045-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
322-326
Název nakladatele
Neuveden
Místo vydání
Dillí, Indie
Místo konání akce
Dept. of ECE, ASET, Amity University, Noida Sec-
Datum konání akce
22. 2. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000446953700061