New experimental research stand SVICKA neutron field analysis using neutron activation detector technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F18%3APU127812" target="_blank" >RIV/00216305:26220/18:PU127812 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.epj-conferences.org/articles/epjconf/abs/2018/12/epjconf_ayss2018_01004/epjconf_ayss2018_01004.html" target="_blank" >https://www.epj-conferences.org/articles/epjconf/abs/2018/12/epjconf_ayss2018_01004/epjconf_ayss2018_01004.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201817701004" target="_blank" >10.1051/epjconf/201817701004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New experimental research stand SVICKA neutron field analysis using neutron activation detector technique
Popis výsledku v původním jazyce
Knowledge of neutron energy spectra is very important because neutrons with various energies have a different material impact or a biological tissue impact. This paper presents basic results of the neutron flux distribution inside the new experimental research stand SVICKA which is located at Brno University of Technology in Brno, Czech Republic. The experiment also focused on the investigation of the sandwich biological shielding quality that protects staff against radiation effects. The set of indium activation detectors was used to the investigation of neutron flux distribution. The results of the measurement provide basic information about the neutron flux distribution inside all irradiation channels and no damage or cracks are present in the experimental research stand biological shielding.
Název v anglickém jazyce
New experimental research stand SVICKA neutron field analysis using neutron activation detector technique
Popis výsledku anglicky
Knowledge of neutron energy spectra is very important because neutrons with various energies have a different material impact or a biological tissue impact. This paper presents basic results of the neutron flux distribution inside the new experimental research stand SVICKA which is located at Brno University of Technology in Brno, Czech Republic. The experiment also focused on the investigation of the sandwich biological shielding quality that protects staff against radiation effects. The set of indium activation detectors was used to the investigation of neutron flux distribution. The results of the measurement provide basic information about the neutron flux distribution inside all irradiation channels and no damage or cracks are present in the experimental research stand biological shielding.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EPJ Web of Conferences
ISSN
2100-014X
e-ISSN
—
Svazek periodika
177
Číslo periodika v rámci svazku
01004
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
6
Strana od-do
1-6
Kód UT WoS článku
000478977000004
EID výsledku v databázi Scopus
2-s2.0-85046803379