Analysis of Passive Heat Removal System by ANSYS CFX software
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F18%3APU127988" target="_blank" >RIV/00216305:26220/18:PU127988 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EPE.2018.8395993" target="_blank" >http://dx.doi.org/10.1109/EPE.2018.8395993</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2018.8395993" target="_blank" >10.1109/EPE.2018.8395993</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of Passive Heat Removal System by ANSYS CFX software
Popis výsledku v původním jazyce
In the current study, the model of Passive Heat Removal System (PHRS) through SG (steam-generator) was developed for computational fluid dynamics (CFD) analysis. During work there was done three main tasks, which are creating geometrical form of PHRS, meshing of model to achieve a better analysis of thermo-hydraulic phenomena and creating domains for simulation steam condensation in PHRS SG heat exchanger tubes. Analysis through the “ANSYS CFX” software, with two different cases investigated at the steam inlet velocity of 1 m/s and 3 m/s. A thorough description of the steam condensation process in the passive cooling system obtained as a result of the analysis. The rate of the steam condensation in heat exchanger pipeline was assessed.
Název v anglickém jazyce
Analysis of Passive Heat Removal System by ANSYS CFX software
Popis výsledku anglicky
In the current study, the model of Passive Heat Removal System (PHRS) through SG (steam-generator) was developed for computational fluid dynamics (CFD) analysis. During work there was done three main tasks, which are creating geometrical form of PHRS, meshing of model to achieve a better analysis of thermo-hydraulic phenomena and creating domains for simulation steam condensation in PHRS SG heat exchanger tubes. Analysis through the “ANSYS CFX” software, with two different cases investigated at the steam inlet velocity of 1 m/s and 3 m/s. A thorough description of the steam condensation process in the passive cooling system obtained as a result of the analysis. The rate of the steam condensation in heat exchanger pipeline was assessed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1210" target="_blank" >LO1210: Energie v podmínkách udržitelného rozvoje (EN-PUR)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proccedings of the 2018 19th International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-5386-4612-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
293-298
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Brno
Datum konání akce
16. 5. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000439649500055