A comparison of two modal analysis methods: An impact hammer versus laser vibrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU132037" target="_blank" >RIV/00216305:26220/20:PU132037 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/ap/article/view/6050" target="_blank" >https://ojs.cvut.cz/ojs/index.php/ap/article/view/6050</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/AP.2020.60.0420" target="_blank" >10.14311/AP.2020.60.0420</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparison of two modal analysis methods: An impact hammer versus laser vibrometry
Popis výsledku v původním jazyce
This paper presents a comparative experimental-analytical study on the performance of Multi-Input Single-Output (MISO) and Single-Input Multi-Output (SIMO) techniques to identify the modal properties of a cantilever beam. A 2-D laser interferometry was employed to perform the SIMO modal test, while for the MISO test configuration, a conventional accelerometer was used to measure the response of the structure. Comparing the experimentally-measured natural frequencies with those calculated by the FEM model, a maximum difference of 4% between natural frequencies was observed. The repeatability of both techniques is also investigated in this paper and it is shown that the difference between modal properties identified under different operators is less than 0.5% for both the MISO and SIMO techniques.
Název v anglickém jazyce
A comparison of two modal analysis methods: An impact hammer versus laser vibrometry
Popis výsledku anglicky
This paper presents a comparative experimental-analytical study on the performance of Multi-Input Single-Output (MISO) and Single-Input Multi-Output (SIMO) techniques to identify the modal properties of a cantilever beam. A 2-D laser interferometry was employed to perform the SIMO modal test, while for the MISO test configuration, a conventional accelerometer was used to measure the response of the structure. Comparing the experimentally-measured natural frequencies with those calculated by the FEM model, a maximum difference of 4% between natural frequencies was observed. The repeatability of both techniques is also investigated in this paper and it is shown that the difference between modal properties identified under different operators is less than 0.5% for both the MISO and SIMO techniques.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica (on-line)
ISSN
1210-2709
e-ISSN
1805-2363
Svazek periodika
60
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
420-427
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85095447589