COMPARISON OF POWER QUALITY MONITOR DATA TRANSMISSION BETWEEN MODBUS TCP/IP AND IEC 60870-5-104
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU136711" target="_blank" >RIV/00216305:26220/20:PU136711 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.fekt.vut.cz/conf/EEICT/archiv/sborniky/EEICT_2020_sbornik_2.pdf" target="_blank" >https://www.fekt.vut.cz/conf/EEICT/archiv/sborniky/EEICT_2020_sbornik_2.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
COMPARISON OF POWER QUALITY MONITOR DATA TRANSMISSION BETWEEN MODBUS TCP/IP AND IEC 60870-5-104
Popis výsledku v původním jazyce
With deployment of smart devices along the electrical grid key infrastructure points, communication process with regards to its volume and load on communication infrastructure needs to be described and evaluated. This article focuses on protocol Modbus TCP/IP and standard IEC 60870-5-104 with regard to their communication structure and principles within substation connected to network by broadband over power lines modems (BPL). This paper also offers two communication scenarios over BPL network by using real substation power quality monitor. Furthermore, performance of each solution is being summed up in the discussion. Conclusion offers a convenient solution for utilization of key values transmission on limited communication channel.
Název v anglickém jazyce
COMPARISON OF POWER QUALITY MONITOR DATA TRANSMISSION BETWEEN MODBUS TCP/IP AND IEC 60870-5-104
Popis výsledku anglicky
With deployment of smart devices along the electrical grid key infrastructure points, communication process with regards to its volume and load on communication infrastructure needs to be described and evaluated. This article focuses on protocol Modbus TCP/IP and standard IEC 60870-5-104 with regard to their communication structure and principles within substation connected to network by broadband over power lines modems (BPL). This paper also offers two communication scenarios over BPL network by using real substation power quality monitor. Furthermore, performance of each solution is being summed up in the discussion. Conclusion offers a convenient solution for utilization of key values transmission on limited communication channel.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20203 - Telecommunications
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings II of the 26th Conference STUDENT EEICT 2020
ISBN
978-80-214-5868-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
234-238
Název nakladatele
Neuveden
Místo vydání
Vysoké učení technické v Brně, Fakulta elektrote
Místo konání akce
BRNO
Datum konání akce
23. 4. 2020
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
000598376500052