An Empirical Study of Fatigue-Induced Electrical Impedance Models of Biceps Tissues
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU137669" target="_blank" >RIV/00216305:26220/20:PU137669 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9222426" target="_blank" >https://ieeexplore.ieee.org/document/9222426</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICUMT51630.2020.9222426" target="_blank" >10.1109/ICUMT51630.2020.9222426</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An Empirical Study of Fatigue-Induced Electrical Impedance Models of Biceps Tissues
Popis výsledku v původním jazyce
Electrical impedance myography (EIM) is a noninvasive approach to muscle assessment based on the measurement of the electrical impedance in frequency range of interest. In this paper, fatigue-induced electrical impedance models of biceps tissues are investigated. After the dataset used is briefly described, complete set of parameters of the modified Fricke model, utilizing Foster I RC network-based fractional-order capacitor (FOC), are computed. The goodness of fitting of proposed FOCs and bioimpedance models were evaluated visually and statistically. The fit accuracy of designed electrical impedance models is R2R,X≥0.9978. Proposed models provide more intuitive representation of the electrical behavior of biceps tissues. EIA standard compliant E96 series lumped parameter-based practical models give an appropriate explanation of fatigue effect on biceps tissues from resistance and capacitance point of view.
Název v anglickém jazyce
An Empirical Study of Fatigue-Induced Electrical Impedance Models of Biceps Tissues
Popis výsledku anglicky
Electrical impedance myography (EIM) is a noninvasive approach to muscle assessment based on the measurement of the electrical impedance in frequency range of interest. In this paper, fatigue-induced electrical impedance models of biceps tissues are investigated. After the dataset used is briefly described, complete set of parameters of the modified Fricke model, utilizing Foster I RC network-based fractional-order capacitor (FOC), are computed. The goodness of fitting of proposed FOCs and bioimpedance models were evaluated visually and statistically. The fit accuracy of designed electrical impedance models is R2R,X≥0.9978. Proposed models provide more intuitive representation of the electrical behavior of biceps tissues. EIA standard compliant E96 series lumped parameter-based practical models give an appropriate explanation of fatigue effect on biceps tissues from resistance and capacitance point of view.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA19-24585S" target="_blank" >GA19-24585S: Syntéza elektrických fantomů věrně popisující fraktální impedanční chování reálných systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT)
ISBN
978-1-7281-9281-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
58-61
Název nakladatele
IEEE
Místo vydání
Brno, Czech Republic
Místo konání akce
Online
Datum konání akce
5. 10. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000627398300010