EXPERIMENTAL INVESTIGATION OF CRITICAL HEAT FLUX IN ANNULUS AT LOW PRESSURE AND LOW FLOW PARAMETERS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU138457" target="_blank" >RIV/00216305:26220/20:PU138457 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/20:00345754
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/APP/article/view/6916" target="_blank" >https://ojs.cvut.cz/ojs/index.php/APP/article/view/6916</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2020.28.0050" target="_blank" >10.14311/APP.2020.28.0050</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EXPERIMENTAL INVESTIGATION OF CRITICAL HEAT FLUX IN ANNULUS AT LOW PRESSURE AND LOW FLOW PARAMETERS
Popis výsledku v původním jazyce
Steady state flow boiling experiments were conducted on a technically smooth Inconel 625 tube with outer diameter 9.1 mm at inlet pressures 131, 220 and 323 kPa, inlet temperatures 62, 78 and 94 °C and approximately 400, 600 and 1000 kg/(m2.s) mass flow. Water of these parameters was entering into the vertically aligned annulus, where the uniformly heated tube was placed until the critical heat flux (CHF) appeared. The experimental data were compared to estimations of CHF by local PGT tube correlation and Groeneveld’s look-up tables for tubes. The results imply that in the region of low pressure and low mass flux, the differences between calculations and experiments are substantial (more than 50 % of CHF). The calculations further imply that look-up tables and tube correlations should be corrected to the annulus geometry. Here, the Doerffer’s approach was chosen and led to a substantial enhancement of CHF estimation. Yet, a new correlation for the region of low pressure and flow is needed.
Název v anglickém jazyce
EXPERIMENTAL INVESTIGATION OF CRITICAL HEAT FLUX IN ANNULUS AT LOW PRESSURE AND LOW FLOW PARAMETERS
Popis výsledku anglicky
Steady state flow boiling experiments were conducted on a technically smooth Inconel 625 tube with outer diameter 9.1 mm at inlet pressures 131, 220 and 323 kPa, inlet temperatures 62, 78 and 94 °C and approximately 400, 600 and 1000 kg/(m2.s) mass flow. Water of these parameters was entering into the vertically aligned annulus, where the uniformly heated tube was placed until the critical heat flux (CHF) appeared. The experimental data were compared to estimations of CHF by local PGT tube correlation and Groeneveld’s look-up tables for tubes. The results imply that in the region of low pressure and low mass flux, the differences between calculations and experiments are substantial (more than 50 % of CHF). The calculations further imply that look-up tables and tube correlations should be corrected to the annulus geometry. Here, the Doerffer’s approach was chosen and led to a substantial enhancement of CHF estimation. Yet, a new correlation for the region of low pressure and flow is needed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/LTAUSA18198" target="_blank" >LTAUSA18198: ADAR - Pokročilý jaderný reaktor řízený urychlovačem</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ŠIMÁNĚ 2020: Student Conference on Nuclear Engineering
ISBN
978-80-01-06794-9
ISSN
2336-5382
e-ISSN
—
Počet stran výsledku
9
Strana od-do
50-58
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
ČVUT v Praze
Datum konání akce
23. 6. 2020
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—