Simulation of Fault Operation of a 13 level CHB Multilevel Converter for Power Coolant Pump
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F21%3APU140600" target="_blank" >RIV/00216305:26220/21:PU140600 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore-ieee-org.ezproxy.lib.vutbr.cz/document/9432556" target="_blank" >https://ieeexplore-ieee-org.ezproxy.lib.vutbr.cz/document/9432556</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PEMC48073.2021.9432556" target="_blank" >10.1109/PEMC48073.2021.9432556</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simulation of Fault Operation of a 13 level CHB Multilevel Converter for Power Coolant Pump
Popis výsledku v původním jazyce
This paper discusses the simulation of the cascaded H-bridge (CHB) multilevel converter for power coolant pump with the demand of high reliability and robustness. Multi-level converters are designed to control medium-voltage motors, energy conversion, active power filtering, and many other applications. First, an overview of the CHB converter, the method of control, and operation under fault conditions is described. The next part deals with the requirements of the application of the converter and the parameters of the simulation system. Then the 13-level multilevel converter is simulated during operation under normal conditions and during operation under abnormal conditions. If the cell is damage, it is bypassed by an auxiliary switch. The simulated voltages and torques were compared with each other. As a result, the converter is able to operate even with three faulty cells without interrupting the operation of the cooling pump.
Název v anglickém jazyce
Simulation of Fault Operation of a 13 level CHB Multilevel Converter for Power Coolant Pump
Popis výsledku anglicky
This paper discusses the simulation of the cascaded H-bridge (CHB) multilevel converter for power coolant pump with the demand of high reliability and robustness. Multi-level converters are designed to control medium-voltage motors, energy conversion, active power filtering, and many other applications. First, an overview of the CHB converter, the method of control, and operation under fault conditions is described. The next part deals with the requirements of the application of the converter and the parameters of the simulation system. Then the 13-level multilevel converter is simulated during operation under normal conditions and during operation under abnormal conditions. If the cell is damage, it is bypassed by an auxiliary switch. The simulated voltages and torques were compared with each other. As a result, the converter is able to operate even with three faulty cells without interrupting the operation of the cooling pump.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TN01000071" target="_blank" >TN01000071: Národní centrum kompetence Mechatroniky a chytrých technologií pro strojírenství</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)
ISBN
978-1-7281-5660-6
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
173-178
Název nakladatele
The Silesian University of Technology, Poland
Místo vydání
Gliwice, Poland
Místo konání akce
Gliwice
Datum konání akce
20. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000723843000024