THE FIRST COSMIC RAY MEASUREMENTS FOR FUTURE MCORD PROJECT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F21%3APU147347" target="_blank" >RIV/00216305:26220/21:PU147347 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.actaphys.uj.edu.pl/fulltext?series=Sup&vol=14&page=537" target="_blank" >https://www.actaphys.uj.edu.pl/fulltext?series=Sup&vol=14&page=537</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5506/APhysPolBSupp.14.537" target="_blank" >10.5506/APhysPolBSupp.14.537</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
THE FIRST COSMIC RAY MEASUREMENTS FOR FUTURE MCORD PROJECT
Popis výsledku v původním jazyce
Multi-Purpose Detector (MPD) is a main detector set for the future Nuclotron-based Ion Collider fAcility (NICA) located in Dubna, Russia. The MPD needs an additional trigger system for off-beam calibration and for the rejection of cosmic ray particles (mainly muons) for full functionality. The prototype Cosmic Ray measurement system for MPD detector is under calibration results of Extended Cosmic Shower (ECS) simulation, we need the real Cosmic Ray (CR) measurement results performed at the NICA location. This article describes the first CR measurements done with the Cosmic Watch simple detectors based on the small 5 cm x 5 cm plastic scintillators with silicon photomultiplier photodetectors (SiPM).
Název v anglickém jazyce
THE FIRST COSMIC RAY MEASUREMENTS FOR FUTURE MCORD PROJECT
Popis výsledku anglicky
Multi-Purpose Detector (MPD) is a main detector set for the future Nuclotron-based Ion Collider fAcility (NICA) located in Dubna, Russia. The MPD needs an additional trigger system for off-beam calibration and for the rejection of cosmic ray particles (mainly muons) for full functionality. The prototype Cosmic Ray measurement system for MPD detector is under calibration results of Extended Cosmic Shower (ECS) simulation, we need the real Cosmic Ray (CR) measurement results performed at the NICA location. This article describes the first CR measurements done with the Cosmic Watch simple detectors based on the small 5 cm x 5 cm plastic scintillators with silicon photomultiplier photodetectors (SiPM).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10300 - Physical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acta Physica Polonica B Proceedings Supplement
ISBN
—
ISSN
1899-2358
e-ISSN
—
Počet stran výsledku
6
Strana od-do
537-542
Název nakladatele
JAGIELLONIAN UNIV
Místo vydání
KRAKOW
Místo konání akce
Varšava
Datum konání akce
21. 10. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000742772400012