Influence of shielding on the dependence of capacitance of planar capacitor on a distance of a measured object
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F22%3APU145372" target="_blank" >RIV/00216305:26220/22:PU145372 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.ifacol.2022.06.026" target="_blank" >https://doi.org/10.1016/j.ifacol.2022.06.026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ifacol.2022.06.026" target="_blank" >10.1016/j.ifacol.2022.06.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of shielding on the dependence of capacitance of planar capacitor on a distance of a measured object
Popis výsledku v původním jazyce
This article deals with the topic of the shielding effect of electrodes in the design of capacitance sensors. The main focus of the article is the phenomenon, which occurs when placing shielding electrodes between planar capacitor electrodes. This phenomenon naturally occurs when the multi-electrode setup is being used. Such setup is used in electronic capacitance tomography (ECT). The first part of the article briefly describes the theoretical attributes of a planar capacitor. Then the model of the multi-electrode system is explained. Subsequently, the experiment during which the phenomenon was observed, is being described. The real measurement is then compared to the simulation of the equal setup. Results, implications, and possible explanations are being discussed in the conclusion.
Název v anglickém jazyce
Influence of shielding on the dependence of capacitance of planar capacitor on a distance of a measured object
Popis výsledku anglicky
This article deals with the topic of the shielding effect of electrodes in the design of capacitance sensors. The main focus of the article is the phenomenon, which occurs when placing shielding electrodes between planar capacitor electrodes. This phenomenon naturally occurs when the multi-electrode setup is being used. Such setup is used in electronic capacitance tomography (ECT). The first part of the article briefly describes the theoretical attributes of a planar capacitor. Then the model of the multi-electrode system is explained. Subsequently, the experiment during which the phenomenon was observed, is being described. The real measurement is then compared to the simulation of the equal setup. Results, implications, and possible explanations are being discussed in the conclusion.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th IFAC Conference on Programmable Devices and Embedded Systems – PDeS 2022.
ISBN
—
ISSN
2405-8963
e-ISSN
—
Počet stran výsledku
6
Strana od-do
158-163
Název nakladatele
Elsevier
Místo vydání
Sarajevo, Bosna a Hercegovina
Místo konání akce
Sarajevo
Datum konání akce
17. 5. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000836230600026