Model of Unsymmetrical Three-Phase Power System
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F22%3APU145526" target="_blank" >RIV/00216305:26220/22:PU145526 - isvavai.cz</a>
Výsledek na webu
<a href="https://eesymp.fei.tuke.sk/viewabstract.php?id=10" target="_blank" >https://eesymp.fei.tuke.sk/viewabstract.php?id=10</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Model of Unsymmetrical Three-Phase Power System
Popis výsledku v původním jazyce
This paper presents extension of the symmetrical components network model to the three-phase in a simulation engine, which is used in the MODES program and in the dispatch training simulator DTS. This extension allows to model network asymmetries in both the fault-free state and faulted operation, even to simulate contemporary multiple asymmetric short-circuit faults. The extended model can be used both for analytical calculations (such as setting protections) and for training dispatchers in solving faults in the distribution. The reliability of the created model is verified using a test system by comparing simulation results with another program that allow three-phase calculation. The test system is topological simple, but it contains several components important for model testing – e.g. arc suppression coil automatic tracking and directional earth fault relay.
Název v anglickém jazyce
Model of Unsymmetrical Three-Phase Power System
Popis výsledku anglicky
This paper presents extension of the symmetrical components network model to the three-phase in a simulation engine, which is used in the MODES program and in the dispatch training simulator DTS. This extension allows to model network asymmetries in both the fault-free state and faulted operation, even to simulate contemporary multiple asymmetric short-circuit faults. The extended model can be used both for analytical calculations (such as setting protections) and for training dispatchers in solving faults in the distribution. The reliability of the created model is verified using a test system by comparing simulation results with another program that allow three-phase calculation. The test system is topological simple, but it contains several components important for model testing – e.g. arc suppression coil automatic tracking and directional earth fault relay.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 11th International Scientific Symposium on Electrical Power Engineering ELEKTROENERGETIKA 2022
ISBN
978-80-553-4104-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
115-119
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
12. 9. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—