A multi-color video-ophthalmoscopes allows to measure the spectral distribution of light absorption of blood in the human retina
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F23%3APU148063" target="_blank" >RIV/00216305:26220/23:PU148063 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10060599/pdf/fmed-10-1125154.pdf" target="_blank" >https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10060599/pdf/fmed-10-1125154.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fmed.2023.1125154" target="_blank" >10.3389/fmed.2023.1125154</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A multi-color video-ophthalmoscopes allows to measure the spectral distribution of light absorption of blood in the human retina
Popis výsledku v původním jazyce
Based on our previously developed mono-color video-ophthalmoscope a multi-color video-ophthalmoscope was developed. Using narrow band transmission filters, this instrument allows to measure the pulsatile cardiac cycle induced blood volume changes in the human retina for any wavelength in the sensitivity range of the used CMOS-camera. In this key experiment, video sequences (8 s, 25 fps, 200 frames) of the optic nerve head (ONH) were acquire for seven wavelengths between 475 nm and 677 nm one after the other. After image registration of all frames of each video sequence (to compensate for eye movements) and trend correction (to compensate for slow intensity changes), the amplitude of the cardiac cycle induced light intensity changes (pulsatile absorption amplitude PAA) can be calculated for all seven wavelengths. The results confirmed that the spectral distribution of PAA (lambda) follows the distribution of the light absorption of blood. The measured values correspond to the absorption of a thin blood layer of about 0.5 mu m thickness.
Název v anglickém jazyce
A multi-color video-ophthalmoscopes allows to measure the spectral distribution of light absorption of blood in the human retina
Popis výsledku anglicky
Based on our previously developed mono-color video-ophthalmoscope a multi-color video-ophthalmoscope was developed. Using narrow band transmission filters, this instrument allows to measure the pulsatile cardiac cycle induced blood volume changes in the human retina for any wavelength in the sensitivity range of the used CMOS-camera. In this key experiment, video sequences (8 s, 25 fps, 200 frames) of the optic nerve head (ONH) were acquire for seven wavelengths between 475 nm and 677 nm one after the other. After image registration of all frames of each video sequence (to compensate for eye movements) and trend correction (to compensate for slow intensity changes), the amplitude of the cardiac cycle induced light intensity changes (pulsatile absorption amplitude PAA) can be calculated for all seven wavelengths. The results confirmed that the spectral distribution of PAA (lambda) follows the distribution of the light absorption of blood. The measured values correspond to the absorption of a thin blood layer of about 0.5 mu m thickness.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-18578S" target="_blank" >GA21-18578S: Funkční zobrazování sítnice s dvěma vlnovými délkami a současnou akvizicí biosignálů pro hodnocení očního krevního oběhu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Medicine
ISSN
2296-858X
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
1-6
Kód UT WoS článku
000959823500001
EID výsledku v databázi Scopus
2-s2.0-85152652688