The Measurement Uncertainty of the Imaging Luminance Measurement Devices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F23%3APU149565" target="_blank" >RIV/00216305:26220/23:PU149565 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Measurement Uncertainty of the Imaging Luminance Measurement Devices
Popis výsledku v původním jazyce
An imaging luminance measuring device (ILMD) is capable of simultaneous luminance measurement in every pixel of captured image. A conventional luminance meter only measures average luminance in defined viewing angle. An imaging luminance measuring device offers more flexibility and complexity to the luminance analysis of region of interest. However, these devices require complex hardware and software calibration and the uncertainty analysis is therefore more difficult than in case of a conventional luminance meter. In this article a reader learns about the estimation of measurement uncertainties of imaging luminance measurement devices based on the digital camera. Expanded uncertainty in luminance measurement depends on settings of a digital camera and is not uniform across the image. Therefore, 3D functions are chosen for best representing of expanded uncertainty.
Název v anglickém jazyce
The Measurement Uncertainty of the Imaging Luminance Measurement Devices
Popis výsledku anglicky
An imaging luminance measuring device (ILMD) is capable of simultaneous luminance measurement in every pixel of captured image. A conventional luminance meter only measures average luminance in defined viewing angle. An imaging luminance measuring device offers more flexibility and complexity to the luminance analysis of region of interest. However, these devices require complex hardware and software calibration and the uncertainty analysis is therefore more difficult than in case of a conventional luminance meter. In this article a reader learns about the estimation of measurement uncertainties of imaging luminance measurement devices based on the digital camera. Expanded uncertainty in luminance measurement depends on settings of a digital camera and is not uniform across the image. Therefore, 3D functions are chosen for best representing of expanded uncertainty.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/CK03000154" target="_blank" >CK03000154: Dynamický jasový analyzátor</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů