In-Field Compliance Testing of an Existing Photovoltaic Power Generating Module
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F24%3APU151353" target="_blank" >RIV/00216305:26220/24:PU151353 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10559510" target="_blank" >https://ieeexplore.ieee.org/document/10559510</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE61521.2024.10559510" target="_blank" >10.1109/EPE61521.2024.10559510</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In-Field Compliance Testing of an Existing Photovoltaic Power Generating Module
Popis výsledku v původním jazyce
This paper focuses on discussion of in-field compliance testing power generating modules (PGMs) within Czechia. Firstly, it describes compliance testing methods that can be used either in laboratory setting or in-field on a PGM connected to a real network. Then, requirements are discussed in the scope of their suitability for the in-field testing. In what follows, architecture of a photovoltaic PGM is discussed and requirements assigned to responsible component are categorized. As some requirements are associated with the approach and practice of specific distribution systems, distribution system operators in Czechia and the difference among their requirements in the scope of in-field testing is summarized. Lastly, the test setup and the authors' experience with in-field testing are presented and discussed.
Název v anglickém jazyce
In-Field Compliance Testing of an Existing Photovoltaic Power Generating Module
Popis výsledku anglicky
This paper focuses on discussion of in-field compliance testing power generating modules (PGMs) within Czechia. Firstly, it describes compliance testing methods that can be used either in laboratory setting or in-field on a PGM connected to a real network. Then, requirements are discussed in the scope of their suitability for the in-field testing. In what follows, architecture of a photovoltaic PGM is discussed and requirements assigned to responsible component are categorized. As some requirements are associated with the approach and practice of specific distribution systems, distribution system operators in Czechia and the difference among their requirements in the scope of in-field testing is summarized. Lastly, the test setup and the authors' experience with in-field testing are presented and discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2024 24th International Scientific Conference on Electric Power Engineering (EPE)
ISBN
979-8-3503-4877-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
294-299
Název nakladatele
IEEE
Místo vydání
NEW YORK
Místo konání akce
Kouty nad Desnou
Datum konání akce
15. 5. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001261334000006