Exploring the Effect of Electrode Material on the Electrical Impedance of Liquid Samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F24%3APU151914" target="_blank" >RIV/00216305:26220/24:PU151914 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/SOUTHEASTCON52093.2024.10500108" target="_blank" >http://dx.doi.org/10.1109/SOUTHEASTCON52093.2024.10500108</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SOUTHEASTCON52093.2024.10500108" target="_blank" >10.1109/SOUTHEASTCON52093.2024.10500108</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Exploring the Effect of Electrode Material on the Electrical Impedance of Liquid Samples
Popis výsledku v původním jazyce
Using a bipolar electrode configuration to collect impedance measurements of a liquid sample captures contributions from the electrode/liquid interface, the liquid, and the instrument used for the measurements. To understand how the selection of electrode material can impact the measured electrical impedance of liquids in this configuration, three liquids (distilled water, ethanol, and citric acid) were measured with three types of electrode materials (copper, gold, and platinum). To facilitate comparisons of the experimental data, a fractional order equivalent circuit model was used to represent this data and reduce its dimensionality. For each liquid, impedance measurements using the different electrodes had different absolute values and fractional-order representations supporting that electrode material does effect the collected measurements of these types of liquids. This is an important consideration when comparing the electrical impedance of similar liquids measured in similar configurations (e.g. bipolar setup) but with variations in electrode material.
Název v anglickém jazyce
Exploring the Effect of Electrode Material on the Electrical Impedance of Liquid Samples
Popis výsledku anglicky
Using a bipolar electrode configuration to collect impedance measurements of a liquid sample captures contributions from the electrode/liquid interface, the liquid, and the instrument used for the measurements. To understand how the selection of electrode material can impact the measured electrical impedance of liquids in this configuration, three liquids (distilled water, ethanol, and citric acid) were measured with three types of electrode materials (copper, gold, and platinum). To facilitate comparisons of the experimental data, a fractional order equivalent circuit model was used to represent this data and reduce its dimensionality. For each liquid, impedance measurements using the different electrodes had different absolute values and fractional-order representations supporting that electrode material does effect the collected measurements of these types of liquids. This is an important consideration when comparing the electrical impedance of similar liquids measured in similar configurations (e.g. bipolar setup) but with variations in electrode material.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10200 - Computer and information sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/GA23-06070S" target="_blank" >GA23-06070S: Základní výzkum v návrhu CMOS prvků fraktálního řádu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE SoutheastCon-Proceedings
ISBN
979-8-3503-1710-7
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1099-1105
Název nakladatele
IEEE
Místo vydání
NEW YORK
Místo konání akce
Atlanta, Georgia
Datum konání akce
15. 3. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001219464000181