Improved systolic peak detection in photoplethysmography signals: focus on atrial fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0191265" target="_blank" >RIV/00216305:26220/26:0191265 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/9982" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/9982</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2024.4.05" target="_blank" >10.14311/CTJ.2024.4.05</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved systolic peak detection in photoplethysmography signals: focus on atrial fibrillation
Popis výsledku v původním jazyce
Photoplethysmography (PPG) is a widely recognized non-invasive optical technique for monitoring blood volume changes. Recently, PPG signals have gained prominence in healthcare applications, including the detection of cardiac arrhythmias. Cardiac arrhythmias represent a significant global health challenge, with particular focus on identifying atrial fibrillation (AF), the most prevalent type. Accurate detection of systolic peaks in PPG signals is crucial for arrhythmia detection and for other applications such as heart rate estimation and heart rate variability analysis. Despite the high accuracy of existing beat detection methods in healthy subjects, the performance in the presence of cardiac arrhythmias is lower. This study employs a deep learning method to enhance the detection of systolic peaks in PPG signals, even in the presence of AF. The model was trained on a dataset comprising 2,477 10-second PPG segments with over 37,000 annotated PPG peaks, including data from AF patients. Our model achieved an F1 score of 97.3 % on the test dataset and F1 score of 94.8 % on the test dataset when considering only AF patients.
Název v anglickém jazyce
Improved systolic peak detection in photoplethysmography signals: focus on atrial fibrillation
Popis výsledku anglicky
Photoplethysmography (PPG) is a widely recognized non-invasive optical technique for monitoring blood volume changes. Recently, PPG signals have gained prominence in healthcare applications, including the detection of cardiac arrhythmias. Cardiac arrhythmias represent a significant global health challenge, with particular focus on identifying atrial fibrillation (AF), the most prevalent type. Accurate detection of systolic peaks in PPG signals is crucial for arrhythmia detection and for other applications such as heart rate estimation and heart rate variability analysis. Despite the high accuracy of existing beat detection methods in healthy subjects, the performance in the presence of cardiac arrhythmias is lower. This study employs a deep learning method to enhance the detection of systolic peaks in PPG signals, even in the presence of AF. The model was trained on a dataset comprising 2,477 10-second PPG segments with over 37,000 annotated PPG peaks, including data from AF patients. Our model achieved an F1 score of 97.3 % on the test dataset and F1 score of 94.8 % on the test dataset when considering only AF patients.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
2336-5552
Svazek periodika
54
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
1-4
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-105001101541