Comparison and recommendations on earthing system measurement and simulation techniques including staged fault method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0199401" target="_blank" >RIV/00216305:26220/26:0199401 - isvavai.cz</a>
Výsledek na webu
<a href="https://digital-library.theiet.org/doi/pdf/10.1049/icp.2025.2112?download=true" target="_blank" >https://digital-library.theiet.org/doi/pdf/10.1049/icp.2025.2112?download=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1049/icp.2025.2112" target="_blank" >10.1049/icp.2025.2112</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison and recommendations on earthing system measurement and simulation techniques including staged fault method
Popis výsledku v původním jazyce
The article introduces the results of thorough measurement of an earthing system in 22 kV compensated network in comparison to the staged fault. A variety of measurements have been carried out including the staged fault, Wenner soil resistivity measurement, 62 % earth resistance measurement with low and high injecting current, touch voltages and potential distribution. A mathematical model of the earthing system was modelled to obtain the theoretical results and compare them with measurements. The aim of measurements was to investigate the impact of high injecting current on the earth resistance measurement. However, a discrepancy was found out leading to possible cause being the discontinuity of the earthing system or uncertainty of actual earthing system design as well as other possible causes. The helpfulness and complementation of each different method is demonstrated while the root cause of the observed discrepancy is investigated. Unfortunately, based on the results it cannot be ruled out whether it can be beneficial to carry out the measurement with high injecting current. However, the results seem to be on a safe side, meaning that conducting the measurement of earth resistance with low current leads to safer designs.
Název v anglickém jazyce
Comparison and recommendations on earthing system measurement and simulation techniques including staged fault method
Popis výsledku anglicky
The article introduces the results of thorough measurement of an earthing system in 22 kV compensated network in comparison to the staged fault. A variety of measurements have been carried out including the staged fault, Wenner soil resistivity measurement, 62 % earth resistance measurement with low and high injecting current, touch voltages and potential distribution. A mathematical model of the earthing system was modelled to obtain the theoretical results and compare them with measurements. The aim of measurements was to investigate the impact of high injecting current on the earth resistance measurement. However, a discrepancy was found out leading to possible cause being the discontinuity of the earthing system or uncertainty of actual earthing system design as well as other possible causes. The helpfulness and complementation of each different method is demonstrated while the root cause of the observed discrepancy is investigated. Unfortunately, based on the results it cannot be ruled out whether it can be beneficial to carry out the measurement with high injecting current. However, the results seem to be on a safe side, meaning that conducting the measurement of earth resistance with low current leads to safer designs.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IET Conference Proceedings
ISBN
—
ISSN
—
e-ISSN
2732-4494
Počet stran výsledku
5
Strana od-do
2454-2458
Název nakladatele
Institution of Engineering and Technology (IET)
Místo vydání
Geneva, Switzerland
Místo konání akce
Ženeva
Datum konání akce
16. 6. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—