Enhancing Signal Collection Efficiency in Liquid Scintillators via Optical Fibre End Treatments for Dosimetry Applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0199717" target="_blank" >RIV/00216305:26220/26:0199717 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.13164/eeict.2025.215" target="_blank" >http://dx.doi.org/10.13164/eeict.2025.215</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.13164/eeict.2025.215" target="_blank" >10.13164/eeict.2025.215</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enhancing Signal Collection Efficiency in Liquid Scintillators via Optical Fibre End Treatments for Dosimetry Applications
Popis výsledku v původním jazyce
This paper presents a systematic evaluation of various optical fibre end modifications aimed at enhancing signal collection from a liquid scintillator. Recognizing the significant potential of optical fibre dosimetry for long-term, high-dose ionising radiation monitoring, our study emphasizes the optimization of scintillation counting, particularly for neutron detection. By immersing the optical fibre in the liquid scintillator, we enhanced light collection and applied several end treatments, including classical cleaving, tapering, etching, and optical lens formation. Comparative analysis reveals that the choice of end treatment influences light transmission efficiency, thereby advancing the performance of scintillation-based detection systems and paving the way for improved radiation dosimetry techniques.
Název v anglickém jazyce
Enhancing Signal Collection Efficiency in Liquid Scintillators via Optical Fibre End Treatments for Dosimetry Applications
Popis výsledku anglicky
This paper presents a systematic evaluation of various optical fibre end modifications aimed at enhancing signal collection from a liquid scintillator. Recognizing the significant potential of optical fibre dosimetry for long-term, high-dose ionising radiation monitoring, our study emphasizes the optimization of scintillation counting, particularly for neutron detection. By immersing the optical fibre in the liquid scintillator, we enhanced light collection and applied several end treatments, including classical cleaving, tapering, etching, and optical lens formation. Comparative analysis reveals that the choice of end treatment influences light transmission efficiency, thereby advancing the performance of scintillation-based detection systems and paving the way for improved radiation dosimetry techniques.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings II of the Conference Student Eeict
ISBN
9788021463202
ISSN
—
e-ISSN
2788-1334
Počet stran výsledku
246
Strana od-do
215-219
Název nakladatele
Brno University of Technology
Místo vydání
—
Místo konání akce
Brno
Datum konání akce
29. 4. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—