Lossy Compression of 3-D Statistical Shape and Intensity Models of Femoral Bones Using JPEG 2000
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26230%2F16%3APU122421" target="_blank" >RIV/00216305:26230/16:PU122421 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ifacol.2016.12.020" target="_blank" >http://dx.doi.org/10.1016/j.ifacol.2016.12.020</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ifacol.2016.12.020" target="_blank" >10.1016/j.ifacol.2016.12.020</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lossy Compression of 3-D Statistical Shape and Intensity Models of Femoral Bones Using JPEG 2000
Popis výsledku v původním jazyce
Recent development of computer-assisted medical systems, based on statistical shape analysis, leads to a growing number of emerging shape and appearance models. In this paper, we propose a novel method for a lossy compression of 3-D statistical shape and intensity models exploiting the JPEG 2000 image coding system. We also investigate the influence of the lossy compression on the accuracy of an atlas-based 2D-3D reconstruction, which is one of the common applications of the statistical appearance models. The results revealed the method is highly effective for the intensity information, reaching thousandfold compression ratios without affecting the 2D-3D reconstruction accuracy. The bitrate of shape information can be compressed several times without significant influence on the reconstruction accuracy.
Název v anglickém jazyce
Lossy Compression of 3-D Statistical Shape and Intensity Models of Femoral Bones Using JPEG 2000
Popis výsledku anglicky
Recent development of computer-assisted medical systems, based on statistical shape analysis, leads to a growing number of emerging shape and appearance models. In this paper, we propose a novel method for a lossy compression of 3-D statistical shape and intensity models exploiting the JPEG 2000 image coding system. We also investigate the influence of the lossy compression on the accuracy of an atlas-based 2D-3D reconstruction, which is one of the common applications of the statistical appearance models. The results revealed the method is highly effective for the intensity information, reaching thousandfold compression ratios without affecting the 2D-3D reconstruction accuracy. The bitrate of shape information can be compressed several times without significant influence on the reconstruction accuracy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
<a href="/cs/project/TA04011606" target="_blank" >TA04011606: TraumaTech - Využití moderních technik zpracování obrazových dat a počítačového plánování v traumatologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
14th IFAC Conference on Programmable Devices and Embedded Systems PDES 2016 Brno, Czech Republic, 5-7 October 2016
ISBN
—
ISSN
2405-8963
e-ISSN
—
Počet stran výsledku
6
Strana od-do
115-120
Název nakladatele
Elsevier Science
Místo vydání
Brno / Lednice
Místo konání akce
Brno/Lednice
Datum konání akce
5. 10. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000401255800020