HLOUBKOVÉ PROFILY LABILNÍCH KOVOVÝCH SPECIES V SEDIMENTECH A JEJICH IN SITU MĚŘENÍ TECHNIKOU DIFUZNÍHO GRADIENTU V TENKÉM FILMU
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F03%3APU42066" target="_blank" >RIV/00216305:26310/03:PU42066 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
HLOUBKOVÉ PROFILY LABILNÍCH KOVOVÝCH SPECIES V SEDIMENTECH A JEJICH IN SITU MĚŘENÍ TECHNIKOU DIFUZNÍHO GRADIENTU V TENKÉM FILMU
Popis výsledku v původním jazyce
The technique of diffusive gradients in thin films (DGT) presents a new approach in in-situ measurement of trace metal species in environmental systems. Using the DGT technique, trace metals are measured by their accumulation on a selective chelating resin after passage through a well-defined diffusive gel layer. The layer used in this work has an open structure that allows free diffusion of inorganic labile species and some organic metal complexes. Accumulated metals are subsequently analyzed after wasshing the resin layer with a known volume of acid solution by F AAS for major metals (Fe, Mn) and electrothermal AAS for trace metals (Cd, Pb). The depth profiles in an artificial lake sediment with 0.5 cm resolution for major and trace metals, obtainedusing two DGT units with different thickness of diffusive gel layer (0.4 and 1.2 mm) are discussed. Reliable depth profiles of trace metals in sediments are essential for studies of pollution, trace metal cycling and processes occurring i
Název v anglickém jazyce
IN SITU MEASUREMENT OF DEPTH PROFILES OF LABILE METAL SPECIES IN SEDIMENTS BY TECHNIQUE OF DIFFUSIVE GRADIENTS IN THIN FILMS
Popis výsledku anglicky
IN SITU MEASUREMENT OF DEPTH PROFILES OF LABILE METAL SPECIES IN SEDIMENTS BY TECHNIQUE OF DIFFUSIVE GRADIENTS IN THIN FILMS The technique of diffusive gradients in thin films (DGT) presents a new approach in in-situ measurement of trace metal speciesinenvironmental systems. Using the DGT technique, trace metals are measured by their accumulation on a selective chelating resin after passage through a well-defined diffusive gel layer. The layer used in this work has an open structure that allows fre eediffusion of inorganic labile species and some organic metal complexes. Accumulated metals are subsequently analyzed after washing the resin layer with a known volume of acid solution by F AAS for major metals (Fe, Mn) and electrothermal AAS for tracemetals (Cd, Pb). The depth profiles in an artificial lake sediment with 0.5 cm resolution for major and trace metals, obtained using two DGT units with different thickness of diffusive gel layer (0.4 and 1.2 mm) are discussed. Reliable depth
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemické Listy
ISSN
0009 - 2770
e-ISSN
—
Svazek periodika
97
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
1184-1188
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—