Analýza produktů klouzavého obloukového výboje pomocí technikz SPME
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F05%3APU51153" target="_blank" >RIV/00216305:26310/05:PU51153 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Solid Phase Microextraction Analysis of the Gliding Arc Discharge Products
Popis výsledku v původním jazyce
This work was indeed on the studies of gliding arc plasma discharge with respect to its use in decomposition of volatile organic compounds and on the solid phase microextraction analysis of the discharge products. The simple one stage gliding arc reactorwas used for these experiments. The applied voltage generating the discharge was varied in the range of 3.5 - 4 kV, the dry air and its mixtures with nitrogen, oxygen and argon were used as carrier gas, with flow rate of 1000 - 1600 ml/min. The toluene was used as a model VOC and its maximal decomposition of 73 % was achieved at the oxygen content in carrier gas of 60 %. For measurements with air as a carrier gas, the maximum removal efficiency was 68 %. The exhaust gas was sampled during these experi ments by solid phase extraction technique (sorption tubes) and analyzed by gas chromatography linked to the mass spectrometry. The other part of study was focused on the applicability study of solid phase microextraction technique for the
Název v anglickém jazyce
Solid Phase Microextraction Analysis of the Gliding Arc Discharge Products
Popis výsledku anglicky
This work was indeed on the studies of gliding arc plasma discharge with respect to its use in decomposition of volatile organic compounds and on the solid phase microextraction analysis of the discharge products. The simple one stage gliding arc reactorwas used for these experiments. The applied voltage generating the discharge was varied in the range of 3.5 - 4 kV, the dry air and its mixtures with nitrogen, oxygen and argon were used as carrier gas, with flow rate of 1000 - 1600 ml/min. The toluene was used as a model VOC and its maximal decomposition of 73 % was achieved at the oxygen content in carrier gas of 60 %. For measurements with air as a carrier gas, the maximum removal efficiency was 68 %. The exhaust gas was sampled during these experi ments by solid phase extraction technique (sorption tubes) and analyzed by gas chromatography linked to the mass spectrometry. The other part of study was focused on the applicability study of solid phase microextraction technique for the
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD202%2F03%2FH162" target="_blank" >GD202/03/H162: Pokročilé směry ve fyzice a chemii plazmatu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Week of Doctoral Students, Part II
ISBN
80-86732-59-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
423-428
Název nakladatele
Matfyzpress
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
7. 6. 2005
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—