Popis výsledku v původním jazyce
Sulphonamides are widely used antibiotics in human and veterinary medicine. These compounds have been shown to block biological processes in wastewater treatment plants. Furthermore, bacterial resistence against them has been proven to establish easily.The focus of this research was to developed separation and identification technique for sulphonamides in wastewater. Sulphonamides were concentrated by l/l extraction using ethyl acetate. The HPLC column ZORBAX Eclipse XDB-C18 (150mm x 4.6mm) was used and elution was carried out using gradient mode. As mobile phase was used acetonitrile and 0,1% formic acid in purified water. Sulphonamides were detected using UV absorbance at 270 nm. Average recovery obtained for sulfonamides was 84.1 6.8 %. Limit of quatification (LOQ) for sulfathiazol was 0.5 ng.ml-1 and limit of detection was 0.2 ng.ml-1. The optimized method was used for real samples collected from wastewater treatment plant in University of Veterinary and Pharmaceutical Sciences Br
Název v anglickém jazyce
Determination of sulphonamides in wastewater
Popis výsledku anglicky
Sulphonamides are widely used antibiotics in human and veterinary medicine. These compounds have been shown to block biological processes in wastewater treatment plants. Furthermore, bacterial resistence against them has been proven to establish easily.The focus of this research was to developed separation and identification technique for sulphonamides in wastewater. Sulphonamides were concentrated by l/l extraction using ethyl acetate. The HPLC column ZORBAX Eclipse XDB-C18 (150mm x 4.6mm) was used and elution was carried out using gradient mode. As mobile phase was used acetonitrile and 0,1% formic acid in purified water. Sulphonamides were detected using UV absorbance at 270 nm. Average recovery obtained for sulfonamides was 84.1 6.8 %. Limit of quatification (LOQ) for sulfathiazol was 0.5 ng.ml-1 and limit of detection was 0.2 ng.ml-1. The optimized method was used for real samples collected from wastewater treatment plant in University of Veterinary and Pharmaceutical Sciences Br
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-214-3320-5
Místo vydání
Brno
Název nakladatele resp. objednatele
Brno University of Technology, Faculty of Chemistry
Verze
1
Identifikační číslo nosiče
neuvedeno