Průraz diafragmového výboje v kapalinách
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F07%3APU68450" target="_blank" >RIV/00216305:26310/07:PU68450 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Breakdown of the DC Diaphragm Discharge in Liquids
Popis výsledku v původním jazyce
This paper presents results of breakdown phenomenon in the DC diaphragm discharge generated in water solutions of various electrolytes. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities(50-1400 mikro S/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA. Both voltage and current values during the breakdown were more or less constant in the particular region of selected conductivities (approximately 200-1400 mikro S/cm), these values were only slightly increasing (in the case of current) or decreasing (in the case of voltage), respectively, with the increasing solution conductivity (i.e. electrolyte concentration). Beyond this "stable" region, the breakdown characteristics were strongly dependent on the conductivity and partially on the solution kind, too. Comparison of various electrolytes dissolved in the treated solution show only a slight influence on the breakdown characteristic
Název v anglickém jazyce
Breakdown of the DC Diaphragm Discharge in Liquids
Popis výsledku anglicky
This paper presents results of breakdown phenomenon in the DC diaphragm discharge generated in water solutions of various electrolytes. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities(50-1400 mikro S/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA. Both voltage and current values during the breakdown were more or less constant in the particular region of selected conductivities (approximately 200-1400 mikro S/cm), these values were only slightly increasing (in the case of current) or decreasing (in the case of voltage), respectively, with the increasing solution conductivity (i.e. electrolyte concentration). Beyond this "stable" region, the breakdown characteristics were strongly dependent on the conductivity and partially on the solution kind, too. Comparison of various electrolytes dissolved in the treated solution show only a slight influence on the breakdown characteristic
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proeedings of 3rd International Symposium on Non-Equilibrium Processes, Plasma, Combustion and Atmospheric Phenomena
ISBN
978-5-94588-047-4
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
85-85
Název nakladatele
CIAM
Místo vydání
Moskva
Místo konání akce
Soči
Datum konání akce
24. 6. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—