ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F10%3APU90394" target="_blank" >RIV/00216305:26310/10:PU90394 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.
Popis výsledku v původním jazyce
A study has been conducted for the determination of eight elements (Be, V, Co, Ni, Y, Cd, Pb and Th) by inductively coupled plasma mass spectromentry (ICP-MS) in naturals waters and waters after mining and processing of uranium. An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output 1500 W and concentric nebulizer MicroMist with a cooled Scott chamber was used. The matrix effects was eliminated by using a solution of internal standards 6Li was used for 9Be, 45Sc (51V),72Ge (59Co, 60Ni, 89Y), 103Rh (111Cd), 209Bi (206Pb, 207Pb, 208Pb, 232Th). Monitored interfering elements were K+, Na+, NH4+, Fe2+, Ca2+, Mg2+, Al3+, NO3-, NO2-, SO42-, Cl-, HCO3-. The non-polar sorbents based on Silica (C18, C8 and Phenyl) were conditioned with the Benzyldimethyltetradecylammonium chloride (Zephyramine) or 1-etoxycarbonyl-pentadecyltrimethylammonium bromide (Septonex). The sorption process for the preconcentration of target elements was realized in the presence of 4-(2
Název v anglickém jazyce
ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.
Popis výsledku anglicky
A study has been conducted for the determination of eight elements (Be, V, Co, Ni, Y, Cd, Pb and Th) by inductively coupled plasma mass spectromentry (ICP-MS) in naturals waters and waters after mining and processing of uranium. An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output 1500 W and concentric nebulizer MicroMist with a cooled Scott chamber was used. The matrix effects was eliminated by using a solution of internal standards 6Li was used for 9Be, 45Sc (51V),72Ge (59Co, 60Ni, 89Y), 103Rh (111Cd), 209Bi (206Pb, 207Pb, 208Pb, 232Th). Monitored interfering elements were K+, Na+, NH4+, Fe2+, Ca2+, Mg2+, Al3+, NO3-, NO2-, SO42-, Cl-, HCO3-. The non-polar sorbents based on Silica (C18, C8 and Phenyl) were conditioned with the Benzyldimethyltetradecylammonium chloride (Zephyramine) or 1-etoxycarbonyl-pentadecyltrimethylammonium bromide (Septonex). The sorption process for the preconcentration of target elements was realized in the presence of 4-(2
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů