Popis výsledku v původním jazyce
Reduction of organic solvents consumption as well as replacement of some solvents with less harmful alternatives is required by the green chemistry philosophy. High performance liquid chromatography (HPLC) is a widely used tool in analytical chemistry. Hence, in the green analytical chemistry, a solvent consumption of new liquid chromatography methods should be reduced substantially. Realization of the HPLC with capillary columns thus represents a straightforward option of the significant solvent consumption decrease. Namely, N-fold reduction of the internal column diameter leads to N2-fold reduction of the column cross section and the corresponding flow rate as well. In this presentation, some equations related to the column diameter reduction will behighlighted and resulting demands on the sample injection volume and the photometric detection will be discussed. Acetonitrile is a common organic modifier in HPLC mobile phases due to UV transparency, low viscosity and low reactivity. H
Název v anglickém jazyce
CAPILLARY LIQUID CHROMATOGRAPHY: GREEN ANALYTICAL TECHNIQUE AND SOME SIMPLE WAYS OF ITS REALIZATION
Popis výsledku anglicky
Reduction of organic solvents consumption as well as replacement of some solvents with less harmful alternatives is required by the green chemistry philosophy. High performance liquid chromatography (HPLC) is a widely used tool in analytical chemistry. Hence, in the green analytical chemistry, a solvent consumption of new liquid chromatography methods should be reduced substantially. Realization of the HPLC with capillary columns thus represents a straightforward option of the significant solvent consumption decrease. Namely, N-fold reduction of the internal column diameter leads to N2-fold reduction of the column cross section and the corresponding flow rate as well. In this presentation, some equations related to the column diameter reduction will behighlighted and resulting demands on the sample injection volume and the photometric detection will be discussed. Acetonitrile is a common organic modifier in HPLC mobile phases due to UV transparency, low viscosity and low reactivity. H
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů