Development of an analytical method for the determination of platinum in urban dust in the agglomeration of Brno, Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F15%3APU112489" target="_blank" >RIV/00216305:26310/15:PU112489 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of an analytical method for the determination of platinum in urban dust in the agglomeration of Brno, Czech Republic
Popis výsledku v původním jazyce
This thesis studied conditions for preconcentration and determination of platinum in airborne dust. Octadecyl modified silica gel was tested for solid phase extraction for preconcentration of platinum. The ion associates made from platinum chlorocomplexes with cationic surfactant Septonex (carbaetoxypentadecyl trimethylammonium bromide) were sorbed on modified silica gel in the presence of 0.1 mol.l-1 HCl. The retained amount of platinum was eluted with acetonitrile. Recovery values of platinum from model solution were above 90 %. Platinum in eluate was determined by atomic absorption spectrometry with electrothermal atomization (ET-AAS). Samples of airborne dust particulates from filters were decomposed in aqua regia by microwave extraction. This work published yearly monitoring of platinum content in airborne particulate matter in Brno agglomeration, which was determined for each month. Platinum concentration was obtained in interval 2.3–51.5 pg.m-3 in air, which corresponds to 61.9 – 2997.7 ng.g-1 in airborne dust.
Název v anglickém jazyce
Development of an analytical method for the determination of platinum in urban dust in the agglomeration of Brno, Czech Republic
Popis výsledku anglicky
This thesis studied conditions for preconcentration and determination of platinum in airborne dust. Octadecyl modified silica gel was tested for solid phase extraction for preconcentration of platinum. The ion associates made from platinum chlorocomplexes with cationic surfactant Septonex (carbaetoxypentadecyl trimethylammonium bromide) were sorbed on modified silica gel in the presence of 0.1 mol.l-1 HCl. The retained amount of platinum was eluted with acetonitrile. Recovery values of platinum from model solution were above 90 %. Platinum in eluate was determined by atomic absorption spectrometry with electrothermal atomization (ET-AAS). Samples of airborne dust particulates from filters were decomposed in aqua regia by microwave extraction. This work published yearly monitoring of platinum content in airborne particulate matter in Brno agglomeration, which was determined for each month. Platinum concentration was obtained in interval 2.3–51.5 pg.m-3 in air, which corresponds to 61.9 – 2997.7 ng.g-1 in airborne dust.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fresenius Environmental Bulletin
ISSN
1018-4619
e-ISSN
1610-2304
Svazek periodika
24
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
2070-2075
Kód UT WoS článku
000371185200010
EID výsledku v databázi Scopus
2-s2.0-84978289222