Molecular organization and conformational changesof humic acids in dependence on their concentrationin various aqueous solutions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F15%3APU116016" target="_blank" >RIV/00216305:26310/15:PU116016 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Molecular organization and conformational changesof humic acids in dependence on their concentrationin various aqueous solutions
Popis výsledku v původním jazyce
Conformational changes of humic acids in different aqueous solutions were studied by means of two novelty methods: high resolution ultrasound spectrometry (HRUS) and micro-rheology (mR). Obtained results were compared with those of more conventional method of dynamic light scattering (DLS). The HRUS method is based on the measurement of parameters of ultrasonic waves propagating through the sample. The attenuation describes the decay of the amplitude of the ultrasonic wave with the distance travelled. The velocity is the speed of this wave and is related to the wavelength and the frequency of oscillation of the deformation. It is determined by the density and elasticity of the sample, which is strongly influenced by the molecular arrangement. The mR technics (in contrast to conventional rheology) relies on tracking the motions of the micro-sized tracer particles embedded in the sample. It can give information about a local inhomogeneity especially in the ultra-small scale materials. Ou
Název v anglickém jazyce
Molecular organization and conformational changesof humic acids in dependence on their concentrationin various aqueous solutions
Popis výsledku anglicky
Conformational changes of humic acids in different aqueous solutions were studied by means of two novelty methods: high resolution ultrasound spectrometry (HRUS) and micro-rheology (mR). Obtained results were compared with those of more conventional method of dynamic light scattering (DLS). The HRUS method is based on the measurement of parameters of ultrasonic waves propagating through the sample. The attenuation describes the decay of the amplitude of the ultrasonic wave with the distance travelled. The velocity is the speed of this wave and is related to the wavelength and the frequency of oscillation of the deformation. It is determined by the density and elasticity of the sample, which is strongly influenced by the molecular arrangement. The mR technics (in contrast to conventional rheology) relies on tracking the motions of the micro-sized tracer particles embedded in the sample. It can give information about a local inhomogeneity especially in the ultra-small scale materials. Ou
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1211" target="_blank" >LO1211: Centrum materiálového výzkumu na FCH VUT v Brně - udržitelnost a rozvoj</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
NANOCON 2015 7th Internatonal Conference
ISBN
978-80-87294-63-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
645-650
Název nakladatele
Tanger
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
14. 10. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—