Bisphenol A in waste water in the Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F15%3APU116032" target="_blank" >RIV/00216305:26310/15:PU116032 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bisphenol A in waste water in the Czech Republic
Popis výsledku v původním jazyce
This study was focused on the determination of BPA levels at the inflow and outflow of three waste water treatment plants (WWTP). Two of them treat municipal waste water; the first one situated in Brno-Modřice is two-stage facility with mechanical cleaning followed by biological treatment using activated sludge. Its capacity is more than 600 thousands EI. The second WWTP treats waste water from small spa town Luhačovice in South Moravia (capacity 16 200 EI). The third one is small WWTP treating waste waters form the area and buildings of University of Veterinary and Pharmaceutical Sciences in Brno (UVPS). 24-hour mixed samples were taken at the inflow and outflow of all WWTP. Target compound was isolated using SPE and after derivatization two-dimensional comprehensive gas chromatography with time-of-flight mass spectrometric detection was used for their determination.
Název v anglickém jazyce
Bisphenol A in waste water in the Czech Republic
Popis výsledku anglicky
This study was focused on the determination of BPA levels at the inflow and outflow of three waste water treatment plants (WWTP). Two of them treat municipal waste water; the first one situated in Brno-Modřice is two-stage facility with mechanical cleaning followed by biological treatment using activated sludge. Its capacity is more than 600 thousands EI. The second WWTP treats waste water from small spa town Luhačovice in South Moravia (capacity 16 200 EI). The third one is small WWTP treating waste waters form the area and buildings of University of Veterinary and Pharmaceutical Sciences in Brno (UVPS). 24-hour mixed samples were taken at the inflow and outflow of all WWTP. Target compound was isolated using SPE and after derivatization two-dimensional comprehensive gas chromatography with time-of-flight mass spectrometric detection was used for their determination.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů