Real-time polymerase chain reaction as a tool for evaluation of magnetic poly(glycidyl methacrylate)-based microspheres in molecular diagnostics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F15%3APU116109" target="_blank" >RIV/00216305:26310/15:PU116109 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388971:_____/16:00456153 RIV/61389013:_____/16:00456153 RIV/00216305:26310/16:PU122747
Výsledek na webu
<a href="http://www.eurekaselect.com/138077/article" target="_blank" >http://www.eurekaselect.com/138077/article</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2174/1381612822666151228105006" target="_blank" >10.2174/1381612822666151228105006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-time polymerase chain reaction as a tool for evaluation of magnetic poly(glycidyl methacrylate)-based microspheres in molecular diagnostics
Popis výsledku v původním jazyce
DNA amplification by real-time polymerase chain reaction (RT-PCR) was used for the evaluation of efficiency of polymer coating of magnetic hydrophilic poly(2-hydroxyethyl methacrylate-co-glycidyl methacrylate) (P(HEMA-co-GMA)) and poly(glycidyl methacrylate) (PGMA) microspheres with/without carboxyl groups. The inhibition effect of magnetic microspheres on real-time polymerase chain reaction (RT-PCR) course was evaluated by regression analysis after the addition of different concentrations of tested microspheres to PCR mixtures. Microspheres mostly did not interfere in RT-PCR till the concentration 50 ?g/25?l PCR mixture. No relationship between Fe content (and microsphere diameter) and inhibition effect was found. Microspheres containing carboxyl groups extinguished the fluorescence at lower concentrations (10-20 ?g/25?l PCR mixture) without inhibition of DNA amplification as PCR products were detected using agarose gel electrophoresis. Negative effect of maghemite on PCR course was p
Název v anglickém jazyce
Real-time polymerase chain reaction as a tool for evaluation of magnetic poly(glycidyl methacrylate)-based microspheres in molecular diagnostics
Popis výsledku anglicky
DNA amplification by real-time polymerase chain reaction (RT-PCR) was used for the evaluation of efficiency of polymer coating of magnetic hydrophilic poly(2-hydroxyethyl methacrylate-co-glycidyl methacrylate) (P(HEMA-co-GMA)) and poly(glycidyl methacrylate) (PGMA) microspheres with/without carboxyl groups. The inhibition effect of magnetic microspheres on real-time polymerase chain reaction (RT-PCR) course was evaluated by regression analysis after the addition of different concentrations of tested microspheres to PCR mixtures. Microspheres mostly did not interfere in RT-PCR till the concentration 50 ?g/25?l PCR mixture. No relationship between Fe content (and microsphere diameter) and inhibition effect was found. Microspheres containing carboxyl groups extinguished the fluorescence at lower concentrations (10-20 ?g/25?l PCR mixture) without inhibition of DNA amplification as PCR products were detected using agarose gel electrophoresis. Negative effect of maghemite on PCR course was p
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EB - Genetika a molekulární biologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
CURRENT PHARMACEUTICAL DESIGN
ISSN
1381-6128
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
639-646
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—