The determination of the influence of pH value of curing conditions on Portland cement hydration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F16%3APU121718" target="_blank" >RIV/00216305:26310/16:PU121718 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1877705816317817" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1877705816317817</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2016.07.393" target="_blank" >10.1016/j.proeng.2016.07.393</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The determination of the influence of pH value of curing conditions on Portland cement hydration
Popis výsledku v původním jazyce
Water composition during cement hydration can be changed due to migration of ions from the cement matrix to the solution. The storage of various materials together can lead to transfer of various ions and distortion of results. This article is aimed on the influence of storage environment on the Portland cement hydration and hydrated samples composition. Test specimens were prepared and stored in different environments. Storage environments were ultrapure water and solutions having alkaline and acidic pH value. The mechanical properties were measured after 1, 7 and 28 days. Composition of samples stored in different environment was tested by X-ray diffraction and DTA analysis. (C) 2016 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
Název v anglickém jazyce
The determination of the influence of pH value of curing conditions on Portland cement hydration
Popis výsledku anglicky
Water composition during cement hydration can be changed due to migration of ions from the cement matrix to the solution. The storage of various materials together can lead to transfer of various ions and distortion of results. This article is aimed on the influence of storage environment on the Portland cement hydration and hydrated samples composition. Test specimens were prepared and stored in different environments. Storage environments were ultrapure water and solutions having alkaline and acidic pH value. The mechanical properties were measured after 1, 7 and 28 days. Composition of samples stored in different environment was tested by X-ray diffraction and DTA analysis. (C) 2016 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1211" target="_blank" >LO1211: Centrum materiálového výzkumu na FCH VUT v Brně - udržitelnost a rozvoj</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Procedia Engineering
ISSN
1877-7058
e-ISSN
—
Svazek periodika
151
Číslo periodika v rámci svazku
10 - 17
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
10-17
Kód UT WoS článku
000387482800002
EID výsledku v databázi Scopus
2-s2.0-84985032771