A new method for macrolide antibiotics determination in wastewaters from three different wastewater treatment plants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F17%3APU123875" target="_blank" >RIV/00216305:26310/17:PU123875 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.acs.chtf.stuba.sk/papers/acs_0270.pdf" target="_blank" >http://www.acs.chtf.stuba.sk/papers/acs_0270.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/acs-2017-2018" target="_blank" >10.1515/acs-2017-2018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A new method for macrolide antibiotics determination in wastewaters from three different wastewater treatment plants
Popis výsledku v původním jazyce
An effective and practical method for the determination of macrolide antibiotics azithromycin, clarithromycin, erythromycin and roxithromycin in wastewater samples has been developed. The analytical method combines solid phase extraction followed by a chromatographic separation by hydrophilic interaction liquid chromatography (HILIC) coupled with an ion trap mass spectrometer utilizing the electrospray ionization technique. Detection of positively charged ions was performed in full scan mode from 500 to 900 m/z. The method detection limits and method quantification limits obtained were in the range of 2.03 – 7.59 ng L-1 and 6.08 – 23.84 ng L-1, respectively. Recoveries of solid phase extraction were obtained using SupelTM-Select HLB cartridges ranging from 85.76 % to 92.54 %. All target antibiotics were detected in 100 % of the collected raw influent samples with concentrations varying from 15 ng L-1 to 1849 ng L-1. Azithromycin, clarithromycin and erythromycin were also detected in 100 % of the treated water samples and roxithromycin was present in 96 % of the samples. The highest determined concentration in the treated water samples was 1404 ng L-1 of azithromycin. Based on the determined macrolide concentrations, removal efficiencies of individual wastewater treatment plants were calculated to range from 13 % to 100 %.
Název v anglickém jazyce
A new method for macrolide antibiotics determination in wastewaters from three different wastewater treatment plants
Popis výsledku anglicky
An effective and practical method for the determination of macrolide antibiotics azithromycin, clarithromycin, erythromycin and roxithromycin in wastewater samples has been developed. The analytical method combines solid phase extraction followed by a chromatographic separation by hydrophilic interaction liquid chromatography (HILIC) coupled with an ion trap mass spectrometer utilizing the electrospray ionization technique. Detection of positively charged ions was performed in full scan mode from 500 to 900 m/z. The method detection limits and method quantification limits obtained were in the range of 2.03 – 7.59 ng L-1 and 6.08 – 23.84 ng L-1, respectively. Recoveries of solid phase extraction were obtained using SupelTM-Select HLB cartridges ranging from 85.76 % to 92.54 %. All target antibiotics were detected in 100 % of the collected raw influent samples with concentrations varying from 15 ng L-1 to 1849 ng L-1. Azithromycin, clarithromycin and erythromycin were also detected in 100 % of the treated water samples and roxithromycin was present in 96 % of the samples. The highest determined concentration in the treated water samples was 1404 ng L-1 of azithromycin. Based on the determined macrolide concentrations, removal efficiencies of individual wastewater treatment plants were calculated to range from 13 % to 100 %.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Chemica Slovaca
ISSN
1337-978X
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
7
Strana od-do
47-53
Kód UT WoS článku
000433421900008
EID výsledku v databázi Scopus
—