Corrosion degradation of AZ31 magnesium alloy coated by plasma electrolytic oxidation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F19%3APU139997" target="_blank" >RIV/00216305:26310/19:PU139997 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.trpro.2019.07.010" target="_blank" >http://dx.doi.org/10.1016/j.trpro.2019.07.010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.trpro.2019.07.010" target="_blank" >10.1016/j.trpro.2019.07.010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Corrosion degradation of AZ31 magnesium alloy coated by plasma electrolytic oxidation
Popis výsledku v původním jazyce
Influence of plasma electrolytic oxidation (PEO) coating prepared using DC current technique on corrosion resistance of AZ31 magnesium alloy was studied. Morphology and chemical composition of the PEO coating was evaluated by scanning electron microscopy and EDS analysis respectively. Corrosion characteristics of ground and PEO coated samples were measured using electrochemical impedance spectroscopy (EIS) in 0.1 M NaCl. Scanning Kelvin Probe (SKP) technique was employed in order to investigate degradation mechanism of PEO samples after 24 h of salt spray test (NSS acc. to STN ISO 9227). Results showed that except of improved corrosion resistance of PEO coating, change of degradation mechanism was noticed after salt spray test. (C) 2019 The Authors. Published by Elsevier B.V.
Název v anglickém jazyce
Corrosion degradation of AZ31 magnesium alloy coated by plasma electrolytic oxidation
Popis výsledku anglicky
Influence of plasma electrolytic oxidation (PEO) coating prepared using DC current technique on corrosion resistance of AZ31 magnesium alloy was studied. Morphology and chemical composition of the PEO coating was evaluated by scanning electron microscopy and EDS analysis respectively. Corrosion characteristics of ground and PEO coated samples were measured using electrochemical impedance spectroscopy (EIS) in 0.1 M NaCl. Scanning Kelvin Probe (SKP) technique was employed in order to investigate degradation mechanism of PEO samples after 24 h of salt spray test (NSS acc. to STN ISO 9227). Results showed that except of improved corrosion resistance of PEO coating, change of degradation mechanism was noticed after salt spray test. (C) 2019 The Authors. Published by Elsevier B.V.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Transportation Research Procedia
ISBN
—
ISSN
2352-1465
e-ISSN
—
Počet stran výsledku
8
Strana od-do
51-58
Název nakladatele
ELSEVIER
Místo vydání
AMSTERDAM
Místo konání akce
Novy Smokovec
Datum konání akce
29. 5. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000568460300009