Surface scan cold plasma technology for effective inhibition of Staphylococcus epidermidis and Escherichia coli
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F26%3A0200602" target="_blank" >RIV/00216305:26310/26:0200602 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.nature.com/articles/s41598-025-32902-1" target="_blank" >https://www.nature.com/articles/s41598-025-32902-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-025-32902-1" target="_blank" >10.1038/s41598-025-32902-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surface scan cold plasma technology for effective inhibition of Staphylococcus epidermidis and Escherichia coli
Popis výsledku v původním jazyce
This study examines the decontamination efficacy of cold atmospheric plasma (CAP) against Staphylococcus epidermidis and Escherichia coli, with emphasis on surface scanning parameters and resistance potential. Bacterial cultures on solid nutrient media were treated using a non-thermal microwave plasma torch operated with high-purity argon (4.6) at 5 Slm and 12–13 W. Treatment was systematically varied in scanning direction, speed, and duration. Results indicate that exposure time was the main factor influencing bacterial inhibition, whereas direction and speed exerted only minor effects. E. coli exhibited greater susceptibility compared to S. epidermidis. Repeated exposure experiments revealed no evidence of resistance development.
Název v anglickém jazyce
Surface scan cold plasma technology for effective inhibition of Staphylococcus epidermidis and Escherichia coli
Popis výsledku anglicky
This study examines the decontamination efficacy of cold atmospheric plasma (CAP) against Staphylococcus epidermidis and Escherichia coli, with emphasis on surface scanning parameters and resistance potential. Bacterial cultures on solid nutrient media were treated using a non-thermal microwave plasma torch operated with high-purity argon (4.6) at 5 Slm and 12–13 W. Treatment was systematically varied in scanning direction, speed, and duration. Results indicate that exposure time was the main factor influencing bacterial inhibition, whereas direction and speed exerted only minor effects. E. coli exhibited greater susceptibility compared to S. epidermidis. Repeated exposure experiments revealed no evidence of resistance development.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10400 - Chemical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2026
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
17
Strana od-do
—
Kód UT WoS článku
001667750800001
EID výsledku v databázi Scopus
—