Stability of a dynamic biometric signature created on various devices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26510%2F17%3APU125941" target="_blank" >RIV/00216305:26510/17:PU125941 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/04274644:_____/17:#0000428
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stability of a dynamic biometric signature created on various devices
Popis výsledku v původním jazyce
The paper directly follows on from the prior research on the dynamic biometric signature (DBS), its properties, security, its resistance to forgery, and its stability. In our experiments, we used all the available pads produced by Signotec, which differ from each other in terms of their design, the size of the signature field, resolution, sampling rate, and even the scanning method used – a regular pen or a special pen using the ERT (Electromagnetic Resonance Technology). A less heterogenous sample was used than in the previous cases, as the objective of the experiments was to demonstrate a potential change in the DBS connected with the use of a different device, nevertheless the size of the sample means it is sufficiently statistically representative. The results showed that irrespective of the device used, the stability of scanning of the dynamic biometric signature was high for each person. The signature variability did not significantly differ between the devices for individual people. Once again it was confirmed that the use of the first signature as a “trial”, not included in the results, reduces the signature variability for each participant.
Název v anglickém jazyce
Stability of a dynamic biometric signature created on various devices
Popis výsledku anglicky
The paper directly follows on from the prior research on the dynamic biometric signature (DBS), its properties, security, its resistance to forgery, and its stability. In our experiments, we used all the available pads produced by Signotec, which differ from each other in terms of their design, the size of the signature field, resolution, sampling rate, and even the scanning method used – a regular pen or a special pen using the ERT (Electromagnetic Resonance Technology). A less heterogenous sample was used than in the previous cases, as the objective of the experiments was to demonstrate a potential change in the DBS connected with the use of a different device, nevertheless the size of the sample means it is sufficiently statistically representative. The results showed that irrespective of the device used, the stability of scanning of the dynamic biometric signature was high for each person. The signature variability did not significantly differ between the devices for individual people. Once again it was confirmed that the use of the first signature as a “trial”, not included in the results, reduces the signature variability for each participant.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
50901 - Other social sciences
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 51th Annual 2017 International Carnahan Conference on Security Technology
ISBN
978-1-5386-1585-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
ICCST
Místo vydání
madrid
Místo konání akce
Madrid
Datum konání akce
23. 10. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000424779200025