Lead detection on direct grown CNTs based working mikroelectrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F12%3APU98784" target="_blank" >RIV/00216305:26620/12:PU98784 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lead detection on direct grown CNTs based working mikroelectrode
Popis výsledku v původním jazyce
The aim of this paper is to show the possibilities of heavy metals electrochemical detection on direct grown multiwalled carbon nanotubes (MWNTs) based microelectrode. The electrode substrate was fabricated using standard lithography and thin film technology on silicon substrate. The working electrode (WE) deposition in a form of vertically aligned MWNTs was done on the electrode substrate using CVD. Fabricated electrodes were tested optically using scanning electron microscopy with good result and electrochemically using electrochemical detection of lead ions in acetate buffer solution. The electrochemical measurement confirmed the suitability of fabricated electrode for lead with the detection limit of 3 umol/L. Finally the comparison of fabricated WE with the WE from commercial electrochemical based on carbon nanotubes (CNTs) have been done resulting in almost two times better sensitivity of our electrode.
Název v anglickém jazyce
Lead detection on direct grown CNTs based working mikroelectrode
Popis výsledku anglicky
The aim of this paper is to show the possibilities of heavy metals electrochemical detection on direct grown multiwalled carbon nanotubes (MWNTs) based microelectrode. The electrode substrate was fabricated using standard lithography and thin film technology on silicon substrate. The working electrode (WE) deposition in a form of vertically aligned MWNTs was done on the electrode substrate using CVD. Fabricated electrodes were tested optically using scanning electron microscopy with good result and electrochemically using electrochemical detection of lead ions in acetate buffer solution. The electrochemical measurement confirmed the suitability of fabricated electrode for lead with the detection limit of 3 umol/L. Finally the comparison of fabricated WE with the WE from commercial electrochemical based on carbon nanotubes (CNTs) have been done resulting in almost two times better sensitivity of our electrode.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XII. Pracovní setkání fyzikálních chemiků a elektrochemiků
ISBN
978-80-7375-618-5
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
251-253
Název nakladatele
Neuveden
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
30. 5. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce