This paper reports on characterization of tin dioxide (SnO2) sensors for methane detection in the air atmosphere and determination of the optimal temperature range to achieve high sensitivity. There were done two measurement of our SnO2 thick film sensoron two different temperatures (240st C and 380st C) and compared with commercial sensor Figaro TGS 822. It was found that the sensitivity of our SnO2 sensor is the same at both temperatures we tested. In comparison of our SnO2 sensor with the commercialsensor Figaro TGS 822 was found that our SnO2 sensor has not a very high sensitivity for lower concentrations, but the saturation level is higher. It means that our SnO2 sensor is able to determine accurately the higher concentrations than the commercial sensor. We were able to determine methane in the concentration range from 50 to 4000 ppm.
Název v anglickém jazyce
Tin dioxide sensor for methane detection
Popis výsledku anglicky
This paper reports on characterization of tin dioxide (SnO2) sensors for methane detection in the air atmosphere and determination of the optimal temperature range to achieve high sensitivity. There were done two measurement of our SnO2 thick film sensoron two different temperatures (240st C and 380st C) and compared with commercial sensor Figaro TGS 822. It was found that the sensitivity of our SnO2 sensor is the same at both temperatures we tested. In comparison of our SnO2 sensor with the commercialsensor Figaro TGS 822 was found that our SnO2 sensor has not a very high sensitivity for lower concentrations, but the saturation level is higher. It means that our SnO2 sensor is able to determine accurately the higher concentrations than the commercial sensor. We were able to determine methane in the concentration range from 50 to 4000 ppm.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XII. Pracovní setkání fyzikálních chemiků a elektrochemiků
ISBN
978-80-7375-618-5
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
54-56
Název nakladatele
LITERA BRNO
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
30. 5. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—