Sequences of pandemic-causing viruses isolated and detected by paramagnetic particles coupled with microfluidic system and electrochemical detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F13%3APU104844" target="_blank" >RIV/00216305:26620/13:PU104844 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/13:00204831
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sequences of pandemic-causing viruses isolated and detected by paramagnetic particles coupled with microfluidic system and electrochemical detector
Popis výsledku v původním jazyce
Detection of the specific sequences of pandemic-causing viral nucleic acids is area attracting numerous scientists worldwide. In this study, we focused on the isolation and detection of oligonucleotide specific sequences of life-threatening viruses (HIV(GAGCAGTGGGAATA), Influenza (TAATAACCATTGGA) and Ebola (ACCTCACTAGAAAA)) by flow injection analysis with electrochemical detection coupled with paramagnetic particles based isolation. All of used viral genomic sequences contained A6 adenine repetition onthe 5 end. This modification enables us to bind them on paramagnetic particle anchoring T25 (MPs-(dT)25). The isolated sequences were subsequently hydrolysed by optimized method using microwaves to obtain single adenines. The obtained samples were detected by microfluidic tool based on stopped flow injection analysis with glassy carbon electrode in the presence of Cu(II)/or CuS nanoparticles to enhance sensitivity and to lower detection limit for adenine. Basic detection parameters as a
Název v anglickém jazyce
Sequences of pandemic-causing viruses isolated and detected by paramagnetic particles coupled with microfluidic system and electrochemical detector
Popis výsledku anglicky
Detection of the specific sequences of pandemic-causing viral nucleic acids is area attracting numerous scientists worldwide. In this study, we focused on the isolation and detection of oligonucleotide specific sequences of life-threatening viruses (HIV(GAGCAGTGGGAATA), Influenza (TAATAACCATTGGA) and Ebola (ACCTCACTAGAAAA)) by flow injection analysis with electrochemical detection coupled with paramagnetic particles based isolation. All of used viral genomic sequences contained A6 adenine repetition onthe 5 end. This modification enables us to bind them on paramagnetic particle anchoring T25 (MPs-(dT)25). The isolated sequences were subsequently hydrolysed by optimized method using microwaves to obtain single adenines. The obtained samples were detected by microfluidic tool based on stopped flow injection analysis with glassy carbon electrode in the presence of Cu(II)/or CuS nanoparticles to enhance sensitivity and to lower detection limit for adenine. Basic detection parameters as a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE
ISSN
1452-3981
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
15
Strana od-do
12628-12642
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—