Numerical refocusing in digital holographic microscopy with extended-sources illumination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F13%3APU106006" target="_blank" >RIV/00216305:26620/13:PU106006 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical refocusing in digital holographic microscopy with extended-sources illumination
Popis výsledku v původním jazyce
Numerical refocusing can be seen as a method of compensating the defocus aberration based on deconvolution by inverse filtering [1] in digital holographic microscopy (DHM). It is well-understood in cases when a coherent (ie point and monochromatic) lightsource such as a collimated laser beam is used [2]. This paper extends the theory to the case of illumination by a quasi-monochromatic extended (spatially incoherent) source. Refocusing methods for spatially incoherent illumination are derived and benefits of this type of illumination are demonstrated. We have proved both theoretically and experimentally that coherent-based refocusing gives incorrect results for extended-source illumination, while results obtained using the newly derived method are correct.
Název v anglickém jazyce
Numerical refocusing in digital holographic microscopy with extended-sources illumination
Popis výsledku anglicky
Numerical refocusing can be seen as a method of compensating the defocus aberration based on deconvolution by inverse filtering [1] in digital holographic microscopy (DHM). It is well-understood in cases when a coherent (ie point and monochromatic) lightsource such as a collimated laser beam is used [2]. This paper extends the theory to the case of illumination by a quasi-monochromatic extended (spatially incoherent) source. Refocusing methods for spatially incoherent illumination are derived and benefits of this type of illumination are demonstrated. We have proved both theoretically and experimentally that coherent-based refocusing gives incorrect results for extended-source illumination, while results obtained using the newly derived method are correct.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
OPTICS EXPRESS
ISSN
1094-4087
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
28258-28271
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—