Popis výsledku v původním jazyce
The paper is focused on practical determination of piezoelectric materials’ behaviour at high temperatures near the Curie point. Temperature dependence of piezoelectric, elastic and dielectric coefficients near the Curie point is important yet hardly measurable material property of piezoelectric ceramics. Various methods can be used for measurement of temperature dependence of piezoelectric parameters and for the determination of the Curie point. Three methods have mostly been used for that purpose - a frequency method, X-ray diffraction spectroscopy (XRD) method and a thermal differential scanning calorimetry (DSC) analysis. These methods were also selected in this study, described in more detail and their results were compared with respect to achievable accuracy and requirements on instrumentation and preparation of samples. Cylinders of hard NCE41 and soft NCE55, NCE51 and PCM51 ceramics obtained from the company Noliac Ceramics were used for material coefficients temperature dependencies determin
Název v anglickém jazyce
Comparison of Methods for Measurement of Curie Temperature
Popis výsledku anglicky
The paper is focused on practical determination of piezoelectric materials’ behaviour at high temperatures near the Curie point. Temperature dependence of piezoelectric, elastic and dielectric coefficients near the Curie point is important yet hardly measurable material property of piezoelectric ceramics. Various methods can be used for measurement of temperature dependence of piezoelectric parameters and for the determination of the Curie point. Three methods have mostly been used for that purpose - a frequency method, X-ray diffraction spectroscopy (XRD) method and a thermal differential scanning calorimetry (DSC) analysis. These methods were also selected in this study, described in more detail and their results were compared with respect to achievable accuracy and requirements on instrumentation and preparation of samples. Cylinders of hard NCE41 and soft NCE55, NCE51 and PCM51 ceramics obtained from the company Noliac Ceramics were used for material coefficients temperature dependencies determin
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20504 - Ceramics
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů