Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F19%3APU132121" target="_blank" >RIV/00216305:26620/19:PU132121 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0963869518303700" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0963869518303700</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ndteint.2019.02.008" target="_blank" >10.1016/j.ndteint.2019.02.008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples
Popis výsledku v původním jazyce
Metallic parts made by selective laser melting technology are evaluated for internal porosity. The non-standardized pores segmentation is one of the key aspects to apply in order to achieve a precise porosity measurement using X-ray computed micro tomography. In this work, we present a new porosity analysis procedure which is based on the global thresholding and the correlation with metallographic image data. The procedure is independent on the obtained voxel resolution and makes an analysis reproducible. The novelty of this work is that the computed tomography is used for a comparative porosity analysis of samples from separate measurements. The functionality of proposed procedure is demonstrated on a test sample of aluminium alloy and is compared to standardly used procedures
Název v anglickém jazyce
Computed tomography based procedure for reproducible porosity measurement of additive manufactured samples
Popis výsledku anglicky
Metallic parts made by selective laser melting technology are evaluated for internal porosity. The non-standardized pores segmentation is one of the key aspects to apply in order to achieve a precise porosity measurement using X-ray computed micro tomography. In this work, we present a new porosity analysis procedure which is based on the global thresholding and the correlation with metallographic image data. The procedure is independent on the obtained voxel resolution and makes an analysis reproducible. The novelty of this work is that the computed tomography is used for a comparative porosity analysis of samples from separate measurements. The functionality of proposed procedure is demonstrated on a test sample of aluminium alloy and is compared to standardly used procedures
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-23274S" target="_blank" >GA15-23274S: Vývoj pokročilých materiálů s využitím metody laserového spékaní</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
NDT & E INTERNATIONAL
ISSN
0963-8695
e-ISSN
1879-1174
Svazek periodika
103
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
111-118
Kód UT WoS článku
000465055800012
EID výsledku v databázi Scopus
2-s2.0-85062443737