Nanoparticle Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) as a technique for elemental analysis of microdrops at sub ppm level
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F19%3APU134483" target="_blank" >RIV/00216305:26620/19:PU134483 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.csi2019mexico.com/index.php/programme/abstracts-book" target="_blank" >http://www.csi2019mexico.com/index.php/programme/abstracts-book</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nanoparticle Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) as a technique for elemental analysis of microdrops at sub ppm level
Popis výsledku v původním jazyce
Nanoparticle Enhanced Laser-Induced Breakdown Spectroscopy (NELIBS) is recently used modification of LIBS technique, where the use of nanoparticles decreases Limits Of Detection (LOD) or even in some particular cases enables the detection of minor elements not detectable with conventional LIBS. In the previous studies NELIBS applications have been presented on different kinds of samples such as metals, transparent samples, fresh samples and liquids. As it is well-known, solutions can be successfully analysed with LIBS either directly in the liquid phase, e.g. by Double Pulse (DP) techniques or by depositing and drying drops of solution on a substrate. While DP-LIBS enables analysis of solutions down to ppm levels, the method of drying several drops of solution virtually does not have any LOD limitation, as far as there is no restriction in the available amount of solution. On the contrary, if only few microliters of solution are available for the analysis, sensitivity can become a major issue in LIBS
Název v anglickém jazyce
Nanoparticle Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) as a technique for elemental analysis of microdrops at sub ppm level
Popis výsledku anglicky
Nanoparticle Enhanced Laser-Induced Breakdown Spectroscopy (NELIBS) is recently used modification of LIBS technique, where the use of nanoparticles decreases Limits Of Detection (LOD) or even in some particular cases enables the detection of minor elements not detectable with conventional LIBS. In the previous studies NELIBS applications have been presented on different kinds of samples such as metals, transparent samples, fresh samples and liquids. As it is well-known, solutions can be successfully analysed with LIBS either directly in the liquid phase, e.g. by Double Pulse (DP) techniques or by depositing and drying drops of solution on a substrate. While DP-LIBS enables analysis of solutions down to ppm levels, the method of drying several drops of solution virtually does not have any LOD limitation, as far as there is no restriction in the available amount of solution. On the contrary, if only few microliters of solution are available for the analysis, sensitivity can become a major issue in LIBS
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
21001 - Nano-materials (production and properties)
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů