Triple-pulse LIBS: Laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F20%3APU135302" target="_blank" >RIV/00216305:26620/20:PU135302 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/20:00115595
Výsledek na webu
<a href="https://pubs.rsc.org/en/content/articlelanding/2020/JA/C9JA00323A#!divAbstract" target="_blank" >https://pubs.rsc.org/en/content/articlelanding/2020/JA/C9JA00323A#!divAbstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/C9JA00323A" target="_blank" >10.1039/C9JA00323A</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Triple-pulse LIBS: Laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses
Popis výsledku v původním jazyce
The goal of this work is to examine the effect of a third additional laser pulse on orthogonal double-pulse laser-induced breakdown spectroscopy (DP LIBS). Namely, a pre-ablation laser pulse and re-heating laser pulse were combined into triple-pulse LIBS (3P LIBS) to achieve plasma emission enhancement. The experiment was designed with emphasis on causing minimal sample damage by utilizing nanosecond laser pulses. It means that the energy of ablation laser pulses was set to the minimal value for which the intensities of selected spectral lines were above the limits of detection. This energy as well as the energies of the pre-ablation and the re-heating laser pulses were kept constant for all experimental arrangements. The interpulse delays for both DP LIBS and for 3P LIBS configurations were optimized for signal enhancements. The 3P LIBS results showed up to 5-fold improvement of the signal to background ratio compared with both DP LIBS arrangements and up to 228-fold improvement in comparison to conventional SP LIBS. In addition, it has been shown that the spectral lines with a higher value of excitation energy prove higher enhancement in both DP LIBS and 3P LIBS configurations. To explain this effect, the dimensions of ablation craters were measured for each configuration using a 3D optical microscope and the temperature was determined from the slope of the Boltzmann plot. It was shown that the pre-ablation causes an increase of ablation crater dimensions and the re-heating increases the plasma temperature.
Název v anglickém jazyce
Triple-pulse LIBS: Laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses
Popis výsledku anglicky
The goal of this work is to examine the effect of a third additional laser pulse on orthogonal double-pulse laser-induced breakdown spectroscopy (DP LIBS). Namely, a pre-ablation laser pulse and re-heating laser pulse were combined into triple-pulse LIBS (3P LIBS) to achieve plasma emission enhancement. The experiment was designed with emphasis on causing minimal sample damage by utilizing nanosecond laser pulses. It means that the energy of ablation laser pulses was set to the minimal value for which the intensities of selected spectral lines were above the limits of detection. This energy as well as the energies of the pre-ablation and the re-heating laser pulses were kept constant for all experimental arrangements. The interpulse delays for both DP LIBS and for 3P LIBS configurations were optimized for signal enhancements. The 3P LIBS results showed up to 5-fold improvement of the signal to background ratio compared with both DP LIBS arrangements and up to 228-fold improvement in comparison to conventional SP LIBS. In addition, it has been shown that the spectral lines with a higher value of excitation energy prove higher enhancement in both DP LIBS and 3P LIBS configurations. To explain this effect, the dimensions of ablation craters were measured for each configuration using a 3D optical microscope and the temperature was determined from the slope of the Boltzmann plot. It was shown that the pre-ablation causes an increase of ablation crater dimensions and the re-heating increases the plasma temperature.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Analytical Atomic Spectrometry
ISSN
0267-9477
e-ISSN
1364-5544
Svazek periodika
35
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
293-300
Kód UT WoS článku
000514606000004
EID výsledku v databázi Scopus
2-s2.0-85079575541