3D Spatial Resolution Evaluation for Helical CT According to ASTM E1695–95
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F20%3APU135417" target="_blank" >RIV/00216305:26620/20:PU135417 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ndt.net/article/ctc2020/papers/ICT2020_paper_id155.pdf" target="_blank" >https://www.ndt.net/article/ctc2020/papers/ICT2020_paper_id155.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
3D Spatial Resolution Evaluation for Helical CT According to ASTM E1695–95
Popis výsledku v původním jazyce
Knowledge of valid spatial resolution is essential for qualitative analysis using X-ray computed tomography. Due to spatial resolution, it is possible to determine with what detectability the imaging system can measure an internal structure. Based on the spatial resolution knowledge, the smallest object size that can be distinguished in resulting images can be determined. Each component in the imaging system affects the value of spatial resolution, and the final value is defined as a product of all comprised components. In this paper, spatial resolution according to standard ASTM E1695–95 was calculated. This standard uses edge response function (ERF), point spread function (PSF) to modulation transfer function (MTF) approach for the calculation of spatial resolution in each plane. For the calculation was used a sphere phantom, which is convenient for the study of spatial resolution in all three orthogonal planes. Spatial resolution was tested on spheres from two different materials, to observe the ef
Název v anglickém jazyce
3D Spatial Resolution Evaluation for Helical CT According to ASTM E1695–95
Popis výsledku anglicky
Knowledge of valid spatial resolution is essential for qualitative analysis using X-ray computed tomography. Due to spatial resolution, it is possible to determine with what detectability the imaging system can measure an internal structure. Based on the spatial resolution knowledge, the smallest object size that can be distinguished in resulting images can be determined. Each component in the imaging system affects the value of spatial resolution, and the final value is defined as a product of all comprised components. In this paper, spatial resolution according to standard ASTM E1695–95 was calculated. This standard uses edge response function (ERF), point spread function (PSF) to modulation transfer function (MTF) approach for the calculation of spatial resolution in each plane. For the calculation was used a sphere phantom, which is convenient for the study of spatial resolution in all three orthogonal planes. Spatial resolution was tested on spheres from two different materials, to observe the ef
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů